Back to Home

Power stability, linewidth, beam quality

MSL-R-721721 nm red CW laser

721 nm

MSL-R-721 is a 721 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 300~1000 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-R-721

21 specification rows

Wavelength721 nm
Output / average power300~1000 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours, ±3°C)<3%, <2%, <1%
Transverse modeTEM00
Longitudinal modeSingle
Noise of amplitude (rms, 20Hz-20MHz)<0.5%
M2<1.3
Beam diameter at the aperture (1/e2, mm)~1.5
Polarization ratio>100:1, Vertical (Horizontal optional)
Spectral line width (nm)<5MHz
Pointing stability over temperature (μrad/°C)<8
Cooled method (water cooled)WCH-580
Operating temperature (°C)20-30
Power supply (90-264VAC)PSU-W-FDA
Expected lifetime (hours)>10000
<1.3
Beam divergence, full angle (mrad)<1.5
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Coherent length (m)>50
Warm-up time (minutes)<15

Applications

Typical uses for lasers of this wavelength and type in this catalogue.

  • Flow cytometry
  • DNA sequencing
  • Medical imaging
  • Collimation
  • Laser medical treatment

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector