MSL-R-721 is a 721 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, collimation. Laser. Key specifications: output / average power 300~1000 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)
<50
Coherent length (m)
>50
Warm-up time (minutes)
<15
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
MSL-R-721: 721 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
MSL-R-721: 721 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
MSL-R-721: 721 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Collimation
MSL-R-721: Collimation benefits from a stable, focusable source. 721 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect MSL-R-721 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.3
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MSL-R-721
What cooling does the MSL-R-721 require?+
Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MSL-R-721 deliver?+
Transverse mode: TEM00 · M2: <1.3. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MSL-R-721 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.