Back to Home

SLM, narrow linewidth, coherence

MSL-R-721721 nm red narrow-linewidth single-frequency laser

721 nm

MSL-R-721 is a 721 nm Single-Frequency laser. Used for dna sequencing, cell sorting, spectrum analysis, flow cytometry. M²: <1.3. Key specifications: output / average power 300~1000 mW, spectral linewidth <5 MHz, optical noise <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-R-721

20 specification rows

Wavelength721 nm
Output / average power300~1000 mW
Spectral linewidth<5 MHz
Optical noise<0.5%
<1.3
Operating modeCW
Power stability (rms, 4 hours, ±3°C)<3%, <2%, <1%
Transverse modeTEM00
Longitudinal modeSingle
Beam diameter at the aperture (1/e2, mm)~1.5
Polarization ratio>100:1, Vertical (Horizontal optional)
Pointing stability over temperature (μrad/°C)<8
Cooled method (water cooled)WCH-580
Operating temperature (°C)20-30
Power supply (90-264VAC)PSU-W-FDA
Expected lifetime (hours)>10000
Noise of amplitude (rms, 20Hz-20MHz)<0.5%
Beam divergence, full angle (mrad)<1.5
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Coherent length (m)>50
Warm-up time (minutes)<15

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

MSL-R-721: 721 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Cell sorting

MSL-R-721: 721 nm emission determines compatible optics, coatings and detectors for Cell sorting. The catalogued beam parameter (<1.3) helps predict how the source will focus and propagate through the instrument.

Spectrum analysis

MSL-R-721: 721 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (<1.3) also controls focusing and collection geometry.

Flow cytometry

MSL-R-721: 721 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MSL-R-721 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
M²: <1.3 · Transverse mode: TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-R-721

What cooling does the MSL-R-721 require?

Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-R-721 deliver?

M²: <1.3 · Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-R-721 with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-R-721 (current)721MSL-FN-720
Wavelength721 nm721 nm720 nm
Optical power / pulse energy300~1000 mW1~300 mW1~100 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam quality<1.3<1.2Confirm for this model