Collimation
MLL-FN-721: Collimation benefits from a stable, focusable source. 721 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
Power stability, linewidth, beam quality
MLL-FN-721 is a 721 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instrument. Laser. Key specifications: output / average power 1~800 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
22 specification rows
| Output / average power | 1~800 mW |
|---|---|
| Beam / notes | Laser |
| Operating mode | CW |
| Power stability (rms, 4 hours, ±3°C) | <2%, <1%, <0.5% |
| Transverse mode | TEM00 |
| Noise of amplitude (rms, 20Hz-20MHz) | <1%, <0.5% |
| M2 | <1.2 |
| Polarization Ratio | >100:1, Horizontal (Vertical optional) |
| Warm-up time (minutes) | <5 |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-H-FDA |
| Operating voltage (VDC) | PSU-SR-OEM(12V/25A) |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 721±1 |
| Output power (mW) | 1-800 |
| Spectral line width (nm) | <0.1, (<0.003 optional@1-300) |
| M² | <1.2 |
| Beam diameter at the aperture (1/e2, mm) | <2.0 |
| Beam divergence, full angle (mrad) | <1.2 |
| Pointing stability (urad) (over 2 hours after warm-up and ±3°C) | <50 |
| Pointing stability over Temperature (urad/°C) | <8 |
| Beam height from base plate (mm) | 27.4 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MLL-FN-721: Collimation benefits from a stable, focusable source. 721 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MLL-FN-721: 721 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-FN-721: 721 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-FN-721: 721 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MLL-FN-721 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MLL-FN-721 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MLL-FN-721 (current) | MSL-FN-721 | MSL-R-721 |
|---|---|---|---|
| Wavelength | 721 nm | 721 nm | 721 nm |
| Optical power / pulse energy | 1~800 mW | 1~300 mW | 300~1000 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | TEM00 | TEM00 | TEM00 |
Compare the MLL-FN-721 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide