Power stability, linewidth, beam quality
MBL-S-473473 nm blue CW laser
473 nmMBL-S-473 is a 473 nm CW laser. Used for collimation, medical treatment, scientific experiments, optical instrumentation. Features: M² <1.2. Key specifications: output / average power 1~50 mW, spectral linewidth < 0.2 nm, power stability <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
MBL-S-473
22 specification rows
| Output / average power | 1~50 mW |
|---|---|
| Spectral linewidth | < 0.2 nm |
| Power stability | <0.5% |
| M² | <1.2 |
| Beam / notes | Features: M² <1.2 |
| Operating mode | CW |
| Transverse mode | TEM00 |
| Beam diameter at the aperture (1/e2, mm) | <1.0 |
| Beam divergence (mrad) | <1.5 |
| Polarization ratio | >100:1, Vertical (Horizontal optional) |
| Warm-up time (minutes) | <5 |
| Pointing stability over temperature (μrad/°C) | <8 |
| Shock tolerance (6ms) | 7g laterally, 15g vertically |
| Operating temperature (℃) | 10-35 |
| Modulation optional | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
| Power supply (100-240VAC) | PSU-A-F/PSU-A-D |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 473±1 |
| Output power (mW) | 1-50 |
| Pointing stability (μrad) (over 2 hours after warm-up and ±3°C) | <50 |
| Beam height from base plate (mm) | 19 |
| Power consumption (W) | <30 |
Applications
Uses named on this model’s datasheet.
- Collimation
- Medical treatment
- Scientific experiments
- Optical instrumentation
- Laser display
- Laser lighting shows
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related cw lasers