Collimation
MBL-S-473: Collimation benefits from a stable, focusable source. 473 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.2) informs waist size and propagation.
Power stability, linewidth, beam quality
MBL-S-473 is a 473 nm CW laser. Used for collimation, medical treatment, scientific experiments, optical instrumentation. Features: M² <1.2. Key specifications: output / average power 1~50 mW, spectral linewidth < 0.2 nm, power stability <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
22 specification rows
| Output / average power | 1~50 mW |
|---|---|
| Spectral linewidth | < 0.2 nm |
| Power stability | <0.5% |
| M² | <1.2 |
| Beam / notes | Features: M² <1.2 |
| Operating mode | CW |
| Transverse mode | TEM00 |
| Beam diameter at the aperture (1/e2, mm) | <1.0 |
| Beam divergence (mrad) | <1.5 |
| Polarization ratio | >100:1, Vertical (Horizontal optional) |
| Warm-up time (minutes) | <5 |
| Pointing stability over temperature (μrad/°C) | <8 |
| Shock tolerance (6ms) | 7g laterally, 15g vertically |
| Operating temperature (℃) | 10-35 |
| Modulation optional | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional |
| Power supply (100-240VAC) | PSU-A-F/PSU-A-D |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 473±1 |
| Output power (mW) | 1-50 |
| Pointing stability (μrad) (over 2 hours after warm-up and ±3°C) | <50 |
| Beam height from base plate (mm) | 19 |
| Power consumption (W) | <30 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MBL-S-473: Collimation benefits from a stable, focusable source. 473 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.2) informs waist size and propagation.
MBL-S-473: 473 nm emission determines compatible optics, coatings and detectors for Medical treatment. The catalogued beam parameter (<1.2) helps predict how the source will focus and propagate through the instrument.
MBL-S-473: 473 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (<1.2) helps predict how the source will focus and propagate through the instrument.
MBL-S-473: 473 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<1.2) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MBL-S-473 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
M²: <1.2 · Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MBL-S-473 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MBL-S-473 (current) | MSL-S-473-D | MSL-U-473 |
|---|---|---|---|
| Wavelength | 473 nm | 473 nm | 473 nm |
| Optical power / pulse energy | 1~50 mW | 1~30 mW | 1~100 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | <1.2 | TEM00 | TEM00 |
Compare the MBL-S-473 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide