Fiber output, PM options, seed formats
FL-355355 nm UV fiber laser
355 nmFL-355 is a 355 nm Fiber laser. Used for scientific research, biology, instrumentation, laser marking. Key specifications: output / average power 1~1000 mW, pulse energy 1~50 uJ, repetition rate ~20 kHz. View specifications, datasheet and enquiry options from Precisometer.
Specifications
FL-355
21 specification rows
| Output / average power | 1~1000 mW |
|---|---|
| Pulse energy | 1~50 uJ |
| Repetition rate | ~20 kHz |
| Pulse width | ~3 ns |
| Operating mode | Passively Q-switched |
| Power stability (rms, 4 hours ± 3°C) | <3%, <2%, <1% |
| Transverse mode | TEM00 |
| Beam divergence, full angle (mrad) | ~1.0 |
| Polarization ratio | >100:1 Vertical |
| Warm-up time (minutes) | <15 |
| Operating temperature (℃) | 10-35 |
| Operating voltage (VDC) | PSU-FL-FDA (12V/25A) / PSU-FL-OEM (12V/25A) |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 355±1 |
| Average power (mW) | 1-1000 |
| Single pulse energy (µJ) | 1-50 |
| Rep. rate | ~20kHz |
| Pulse duration (ns) | ~3 |
| Peak power (kW) | 1-15 |
| Beam diameter at the aperture (mm) | ~6.0 |
| Beam height from base plate (mm) | 23.5 |
Applications
Uses named on this model’s datasheet.
- Scientific research
- Biology
- Instrumentation
- Laser marking
- Sub-surface engraving
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Related fiber lasers
Compare the FL-355 with nearby fiber lasers across the wavelength range.