TEM-F-760: 760 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
TEM-F-760 is a 760 nm CW laser. High Stability Red Laser; TEM 00. Key specifications: output / average power 1~150 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
16 specification rows
| Output / average power | 1~150 mW |
|---|---|
| Beam / notes | High Stability Red Laser; TEM 00 |
| Operating mode | CW |
| Power stability (rms, 4 hours ± 3°C) | <2%, <1%, <0.5% |
| Warm-up time (minutes) | <5 |
| Operating temperature (°C) | 25±3 |
| Power supply (100-240VAC) | PSU-III-FDA/PSU-III-LED/PSU-A-D |
| Expected lifetime (hours) | >10000 |
| Central wavelength (nm) | 760±10 |
| Transverse mode | TEM00 |
| Ellipticity | >0.95 |
| M² | <1.1 |
| Beam diameter at the aperture (1/e2, mm) | ~1.0 |
| Beam divergence, full angle (mrad) | <1.5 |
| Beam height from base plate (mm) | 25 |
| Modulation option | DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
TEM-F-760: 760 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
TEM-F-760: Laboratory measurement benefits from a stable, focusable source. 760 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
System integration
Use these checks to connect TEM-F-760 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 25±3. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M²: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare TEM-F-760 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
Compare the TEM-F-760 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide