Single Longitudinal Mode Single Frequency457 nm blue single-frequency laser
457 nm
Single Longitudinal Mode Single Frequency is a 457 nm Single-Frequency laser. Used for flow cytometry, dna sequencing, medical imaging, measurement. Key specifications: output / average power 1-350 mW. View specifications, datasheet and enquiry options from Precisometer.
Engineering context for a thin Single-Frequency Lasers record
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near single-frequency lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Typical operating fields in the series
• Output / average power: 1-350 mW
• Output / average power: 1~350 mW
• Output / average power: 350~3500 mW
• Operating mode: CW
• Spectral linewidth: <1 MHz
Beam-quality tolerance context
Nearby series records state M²: <1.2, Beam divergence (mrad): <1.5, Beam divergence, full angle (mrad): <1.2, and Beam divergence, full angle (mrad): <1.0. These are series context, not guaranteed values for Single Longitudinal Mode Single Frequency; confirm them on the order-specific datasheet.
Optical integration schematic
Step 1Laser head and temperature-stabilized base
Step 2Safety shutter and optional optical isolator
Step 3Beam steering, expansion or fiber-launch optics
Step 4Experiment input with wavelength-matched coatings
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
Single Longitudinal Mode Single Frequency: 457 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
DNA sequencing
Single Longitudinal Mode Single Frequency: 457 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Medical imaging
Single Longitudinal Mode Single Frequency: 457 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Measurement
Single Longitudinal Mode Single Frequency: Measurement benefits from a stable, focusable source. 457 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare Single Longitudinal Mode Single Frequency with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.
Selection parameter
Single Longitudinal Mode Single Frequency (current)