Back to Home

SLM, narrow linewidth, coherence

MSL-R-457457 nm blue narrow-linewidth single-frequency laser

457 nm

MSL-R-457 is a 457 nm Single-Frequency laser. Used for flow cytometry, dna sequencing, medical imaging, measurement. M²: <1.2. Key specifications: output / average power 350~3500 mW, spectral linewidth <5 MHz, optical noise <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-R-457

15 specification rows

Wavelength457 nm
Output / average power350~3500 mW
Spectral linewidth<5 MHz
Optical noise<0.5%
<1.2
Operating modeCW
Transverse modeTEM00
Longitudinal modeSingle
Pointing stability over temperature (μrad/°C)<8
Warm-up time (minutes)<15
Cooled method (water cooled)WCH-580
Operating temperature (°C)20-30
Power supply (100-240VAC)PSU-W-FDA
Expected lifetime (hours)>10000
Pointing stability(μrad) (over 2 hours after warm-up and ±3°C)<50
Coherent length (m)>50

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

MSL-R-457: 457 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MSL-R-457: 457 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MSL-R-457: 457 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Measurement

MSL-R-457: Measurement benefits from a stable, focusable source. 457 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.2) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect MSL-R-457 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
M²: <1.2 · Transverse mode: TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-R-457

What cooling does the MSL-R-457 require?

Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-R-457 deliver?

M²: <1.2 · Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-R-457 with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-R-457 (current)Single Longitudinal Mode Single FrequencyNarrow Linewidth
Wavelength457 nm457 nm457 nm
Optical power / pulse energy350~3500 mW1-350 mW1-350 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam quality<1.2Confirm for this modelConfirm for this model