PS-M-620 is a 620 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Picosecond Pulsed Red Laser. Key specifications: output / average power 1~500 mW, operating mode Passively Q-switched, rep. rate (khz) 500-1000. View specifications, datasheet and enquiry options from Precisometer.
Typical uses for this laser type, with the selection logic tied to the model record.
Medical imaging
PS-M-620: 620 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<3%, (<2% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
PS-M-620: 620 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, (<2% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
PS-M-620: 620 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, (<2% optional)) helps keep measured intensity changes attributable to the sample rather than source drift.
Microelectronics
PS-M-620: 620 nm emission determines compatible optics, coatings and detectors for Microelectronics. The catalogued beam parameter (<1) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect PS-M-620 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Water cooled · Operating temperature (℃): 15~35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): ~3.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for PS-M-620
What cooling does the PS-M-620 require?+
Cooled method: Water cooled · Operating temperature (℃): 15~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the PS-M-620 deliver?+
Beam divergence, full angle (mrad): <1 · Beam diameter at the aperture (1/e2,mm): ~3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare PS-M-620 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.