Back to Home

Pulse energy, repetition rate, pulse width

OEM-IR-21202120 nm infrared Q-switched pulsed laser

2120 nm

OEM-IR-2120 is a 2120 nm Pulsed laser. Used for material processing especially for plastics, ophthalmic surgery, dentistry, suppresses the bleeding during operations. Q-switched Infrared Laser. Key specifications: operating mode Q-switched, output / average power 1~10 W, beam divergence, full angle (mrad) <3. View specifications, datasheet and enquiry options from Precisometer.

Specifications

OEM-IR-2120

14 specification rows

Operating modeQ-switched
Output / average power1~10 W
Beam / notesQ-switched Infrared Laser
Beam divergence, full angle (mrad)<3
Power stability (rms, 4 hours±3℃)<5%, <3%
Warm-up time (minutes)<10
Cooled methodWater cooled
Operating temperature (℃)10-30
Power supplyPSU-MIR (3U)
Expected lifetime (hours)>10000
Wavelength (nm)2120±2
Output power (W)1-10
Beam diameter at the aperture (1/e2,mm)<4
Beam height from base plate (mm)26.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Material processing especially for plastics

OEM-IR-2120: Material processing especially for plastics depends on how optical energy is delivered to the target; 2120 nm emission governs absorption, while pulse energy, duration and repetition rate governs peak intensity and heat deposition.

Ophthalmic surgery

OEM-IR-2120: 2120 nm emission determines compatible optics, coatings and detectors for Ophthalmic surgery. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.

Dentistry

OEM-IR-2120: 2120 nm emission determines compatible optics, coatings and detectors for Dentistry. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.

Suppresses the bleeding during operations

OEM-IR-2120: 2120 nm emission determines compatible optics, coatings and detectors for Suppresses the bleeding during operations. The catalogued beam parameter (<3) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect OEM-IR-2120 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water cooled · Operating temperature (℃): 10-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <3 · Beam diameter at the aperture (1/e2,mm): <4
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for OEM-IR-2120

What cooling does the OEM-IR-2120 require?

Cooled method: Water cooled · Operating temperature (℃): 10-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the OEM-IR-2120 deliver?

Beam divergence, full angle (mrad): <3 · Beam diameter at the aperture (1/e2,mm): <4. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare OEM-IR-2120 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterOEM-IR-2120 (current)OEM-AO-2120OEM-AO-2096
Wavelength2120 nm2120 nm2096 nm
Optical power / pulse energy1~10 W1~3 W1~15 W
Operating mode / pulse widthQ-switchedQ-switchedQ-switched
Beam quality<3<3<5