Pulse energy, repetition rate, pulse width

Nanosecond Pulsed637 nm red pulsed laser

637 nm

Nanosecond Pulsed is a 637 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Key specifications: output / average power 1-200 mW, pulse width 10 ns ~10 ms. View specifications, datasheet and enquiry options from Precisometer.

Specifications

Nanosecond Pulsed

3 specification rows

Wavelength637 nm
Output / average power1-200 mW
Beam / notesSeries: Nanosecond Pulsed; Features: Pulse width 10 ns~10 ms
Pulse width10 ns ~10 ms

Series-level technical context

Engineering context for a thin Pulsed Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1-50 mW
  • Output / average power: 1-200 mW
  • Output / average power: 1~50 mW
  • Pulse width: 100~1000 ps
  • Operating mode: Pulsed

Beam-quality tolerance context

Nearby series records state M²: <1.2, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): ~1.0. These are series context, not guaranteed values for Nanosecond Pulsed; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Pump and pulsed laser head
  2. Step 2Safety shutter and optional isolator
  3. Step 3Beam-expansion or focusing optics
  4. Step 4Sample with synchronized trigger or detector

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Medical imaging

Nanosecond Pulsed: 637 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

Nanosecond Pulsed: 637 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

Nanosecond Pulsed: 637 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Microelectronics

Nanosecond Pulsed: 637 nm emission determines compatible optics, coatings and detectors for Microelectronics. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare Nanosecond Pulsed with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterNanosecond Pulsed (current)Picosecond PulsedMDL-NS-637
Wavelength637 nm637 nm637 nm
Optical power / pulse energy1-200 mW1-50 mW1-200 mW
Operating mode / pulse width10 ns ~10 ms100~1000 psPulsed
Beam qualityConfirm for this modelConfirm for this model<1.2