Flow cytometry
MSL-T-411: 411 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Power stability, linewidth, beam quality
MSL-T-411 is a 411 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� Single Longitudinal Mode Violet Blue Laser MSL-T- 411/ 1~80mW Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� �� ��. Key specifications: output / average power 1~80 mW. View specifications, datasheet and enquiry options from Precisometer.
Specifications
2 specification rows
| Wavelength | 411 nm |
|---|---|
| Output / average power | 1~80 mW |
| Beam / notes | Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� Single Longitudinal Mode Violet Blue Laser MSL-T-411/ 1~80 mW Linewidth < 0.000005 nm, Coherent length >30 m �� �� �� �� �� �� �� |
Series-level technical context
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near cw lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): ~2.5×0.2, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for MSL-T-411; confirm them on the order-specific datasheet.
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
MSL-T-411: 411 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MSL-T-411: 411 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MSL-T-411: 411 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MSL-T-411: 411 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MSL-T-411 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MSL-T-411 (current) | MDL-C-410 | TUN-403~406 Wavelength tunable |
|---|---|---|---|
| Wavelength | 411 nm | 410 nm | 410 nm |
| Optical power / pulse energy | 1~80 mW | 1~50 mW | 1~30 mW |
| Operating mode / pulse width | Confirm for this model | Confirm for this model | CW |
| Beam quality | Confirm for this model | Confirm for this model | Near TEM00 |
Compare the MSL-T-411 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide