Back to Home

Power stability, linewidth, beam quality

MDL-C-410410 nm violet CW laser

410 nm

MDL-C-410 is a 410 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, holography. Coherent Length (m): >1. Key specifications: output / average power 1~50 mW, power stability <1%, coherence length >1. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-C-410

4 specification rows

Wavelength410 nm
Output / average power1~50 mW
Power stability<1%
Beam / notesCoherent Length (m): >1
Coherence length>1

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 11 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~30 mW
  • Output / average power: 1~50 mW
  • Output / average power: 1~40 mW
  • Operating mode: CW
  • Spectral linewidth: <0.1 nm

Beam-quality tolerance context

Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): ~2.5×0.2, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for MDL-C-410; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.

Flow cytometry

MDL-C-410: 410 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-C-410: 410 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

MDL-C-410: 410 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Holography

MDL-C-410: 410 nm emission determines compatible optics, coatings and detectors for Holography. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-C-410 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-C-410 (current)TUN-403~406 Wavelength tunableMDL-E-405
Wavelength410 nm410 nm410 nm
Optical power / pulse energy1~50 mW1~30 mW1~50 mW
Operating mode / pulse widthConfirm for this modelCWCW
Beam qualityConfirm for this modelNear TEM00Multimode