Back to Home

Power stability, linewidth, beam quality

MDL-E-405410 nm violet narrow-linewidth CW laser

410 nm

MDL-E-405 is a 410 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Key specifications: output / average power 1~50 mW, spectral linewidth < 0.003 nm, power stability <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-E-405

11 specification rows

Wavelength410 nm
Output / average power1~50 mW
Spectral linewidth< 0.003 nm
Power stability<1%
Operating modeCW
Transverse modeMultimode
Beam divergence, full angle (mrad)~2.5×0.2
Warm-up time (minutes)<5
Cooled methodAir cooled
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA/PSU-H-LED
Expected lifetime (hours)>10000

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MDL-E-405: 410 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-E-405: 410 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-E-405: 410 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-E-405 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): ~2.5×0.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-E-405

What cooling does the MDL-E-405 require?

Cooled method: Air cooled · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-E-405 deliver?

Transverse mode: Multimode · Beam divergence, full angle (mrad): ~2.5×0.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-E-405 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-E-405 (current)MDL-C-410TUN-403~406 Wavelength tunable
Wavelength410 nm410 nm410 nm
Optical power / pulse energy1~50 mW1~50 mW1~30 mW
Operating mode / pulse widthCWConfirm for this modelCW
Beam qualityMultimodeConfirm for this modelNear TEM00