MSL-R-360 is a 360 nm Single-Frequency laser. Used for flow cytometry, dna sequencing, medical imaging, high - precision measurement. M²: <1.2. Key specifications: output / average power 80~300 mW, spectral linewidth <5 MHz, optical noise <0.5%. View specifications, datasheet and enquiry options from Precisometer.
Engineering context for a thin Single-Frequency Lasers record
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 113 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Typical operating fields in the series
• Output / average power: 1~30 mW
• Output / average power: 1~50 mW
• Output / average power: 50~300 mW
• Operating mode: CW
• Spectral linewidth: <1 MHz
Beam-quality tolerance context
Nearby series records state M²: <1.5, M²: <1.2, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): <1.2. These are series context, not guaranteed values for MSL-R-360; confirm them on the order-specific datasheet.
Optical integration schematic
Step 1Laser head and temperature-stabilized base
Step 2Safety shutter and optional optical isolator
Step 3Beam steering, expansion or fiber-launch optics
Step 4Experiment input with wavelength-matched coatings
Application context
Why this design is used
Typical uses for this laser type, with the selection logic tied to the model record.
Flow cytometry
MSL-R-360: 360 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
MSL-R-360: 360 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Medical imaging
MSL-R-360: 360 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
High - precision measurement
MSL-R-360: High - precision measurement benefits from a stable, focusable source. 360 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.2) informs waist size and propagation.
System integration
Integration and compatibility
Use these checks to connect MSL-R-360 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Beam parameters at the output
M²: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MSL-R-360
What beam does the MSL-R-360 deliver?+
M²: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MSL-R-360 with the closest available models in the Single-Frequency Lasers family. Confirm option-dependent values on the final configuration before ordering.