Back to Home

Power stability, linewidth, beam quality

MLL-U-588-SM588 nm yellow CW laser

588 nm

MLL-U-588-SM is a 588 nm CW laser. Used for scientific experiments, collimation, laser medical treatment, scientific experiment. Laser. Key specifications: output / average power 1~100 mW, operating mode CW, transverse mode TEM00 (single mode fiber output). View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-U-588-SM

19 specification rows

Output / average power1~100 mW
Beam / notesLaser
Operating modeCW
Transverse modeTEM00 (single mode fiber output)
M2<1.1
Fiber numerical aperture0.10-0.15
Fiber typeSM fiber (PM fiber optional)
Noise of amplitude (rms, 20Hz-20MHz)<1%
Fiber connectorFC/APC
Fiber jacketPVC (black)
Fiber length1m
Polarization (optional)>50:1 after PM fiber
Warm-up time (minutes)<10
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA
Expected lifetime (hours)>10000
Wavelength (nm)588±1
Output power (mW)1-100
<1.1

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Scientific experiments

MLL-U-588-SM: 588 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.

Collimation

MLL-U-588-SM: Collimation benefits from a stable, focusable source. 588 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00 (single mode fiber output)) informs waist size and propagation.

Laser medical treatment

MLL-U-588-SM: 588 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.

Scientific experiment

MLL-U-588-SM: 588 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (TEM00 (single mode fiber output)) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MLL-U-588-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 (single mode fiber output) · M2: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-U-588-SM

How is the MLL-U-588-SM output delivered?

Fiber type: SM fiber (PM fiber optional) · Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MLL-U-588-SM require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-U-588-SM deliver?

Transverse mode: TEM00 (single mode fiber output) · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-U-588-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-U-588-SM (current)MSL-FN-588MSL-W-588
Wavelength588 nm588 nm588 nm
Optical power / pulse energy1~100 mW1~200 mW200-500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00 (single mode fiber output)TEM00TEM00