Scientific experiments
MLL-U-589: 589 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
Power stability, linewidth, beam quality
MLL-U-589 is a 589 nm CW laser. Used for scientific experiments, medical measurements, instrumentation, spectral analysis. Linewidth< 0.003 nm. Key specifications: output / average power 1~200 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
19 specification rows
| Output / average power | 1~200 mW |
|---|---|
| Beam / notes | Linewidth< 0.003 nm |
| Operating mode | CW |
| Power stability (rms, 4 hours, ±3°C) | <3%, <2%, <1% |
| Spectral line width (nm) | <0.1, <0.003 |
| Transverse mode | TEM00 |
| M2 | <1.2 |
| Beam diameter at the aperture (1/e2, mm) | <1.0 |
| Beam divergence (mrad) | <1.5 |
| Polarization ratio | >100:1, Horizontal (Vertical optional) |
| Warm-up time (minutes) | <5 |
| Pointing stability over temperature (μrad/°C) | <8 |
| Operating temperature (°C) | 10-35 |
| Power supply (100-240VAC) | PSU-H-FDA |
| Expected lifetime (hours) | >10000 |
| Wavelength (nm) | 589±1 |
| M² | <1.2 |
| Pointing stability (μrad) (over 2 hours after warm-up and ±3°C) | <50 |
| Beam height from base plate (mm) | 27.4 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
MLL-U-589: 589 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-U-589: Medical measurements benefits from a stable, focusable source. 589 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MLL-U-589: 589 nm emission determines compatible optics, coatings and detectors for Instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MLL-U-589: 589 nm emission determines compatible optics, coatings and detectors for Spectral analysis. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Use these checks to connect MLL-U-589 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MLL-U-589 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MLL-U-589 (current) | MLL-FN-589 | MLL-U-589-SM |
|---|---|---|---|
| Wavelength | 589 nm | 589 nm | 589 nm |
| Optical power / pulse energy | 1~200 mW | 200-300 mW | 1~100 mW |
| Operating mode / pulse width | CW | CW | CW |
| Beam quality | TEM00 | TEM00 | TEM00 (single mode fiber output) |
Compare the MLL-U-589 with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide