Back to Home

Power stability, linewidth, beam quality

MGL-S-589589 nm yellow CW laser

589 nm

MGL-S-589 is a 589 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instrumentation. Water resistance IP67. Key specifications: output / average power 1~50 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <3%, <2%, <1%, (<0.5% optional). View specifications, datasheet and enquiry options from Precisometer.

Specifications

MGL-S-589

22 specification rows

Output / average power1~50 mW
Beam / notesWater resistance IP67
Operating modeCW
Power stability (rms, 4 hours, ±3°C)<3%, <2%, <1%, (<0.5% optional)
Transverse modeTEM00
M2<1.2
Beam diameter at the aperture (1/e2, mm)<1.0
Beam divergence (mrad)<1.5
Polarization ratio>100:1, Horizontal (Vertical optional)
Warm-up time (minutes)<5
Pointing stability over temperature (μrad/°C)<8
Shock tolerance (6ms)7g laterally, 15g vertically
Operating temperature (℃)10-35
Modulation optionalDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optional
Power supply (100-240VAC)PSU-A-D/ PSU-A-F
Expected lifetime (hours)>10000
Wavelength (nm)589±1
Output power (mW)1-50
<1.2
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)19
Power consumption (W)<30

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MGL-S-589: Collimation benefits from a stable, focusable source. 589 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MGL-S-589: 589 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiments

MGL-S-589: 589 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrumentation

MGL-S-589: 589 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MGL-S-589 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MGL-S-589

What cooling does the MGL-S-589 require?

Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MGL-S-589 deliver?

Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MGL-S-589 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMGL-S-589 (current)MLL-U-589MLL-FN-589
Wavelength589 nm589 nm589 nm
Optical power / pulse energy1~50 mW1~200 mW200-300 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00