Back to Home

Power stability, linewidth, beam quality

MLL-FN-588588 nm yellow CW laser

588 nm

MLL-FN-588 is a 588 nm CW laser. Used for collimation, laser medical treatment, scientific experiments, optical instruments. Laser. Key specifications: output / average power 200-300 mW, operating mode CW, power stability (rms, 4 hours, ±3°c) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-FN-588

15 specification rows

Output / average power200-300 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours, ±3°C)<3%, <2%, <1%
Transverse modeTEM00
Beam diameter at the aperture (1/e2, mm)<1.5
Warm-up time (minutes)<5
Pointing stability over temperature (μrad/°C)<8
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA
Expected lifetime (hours)>10000
Wavelength (nm)588±2
Beam divergence (mrad)<1.5
Pointing stability (μrad) (over 2 hours after warm-up and ±3°C)<50
Beam height from base plate (mm)27.4

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MLL-FN-588: Collimation benefits from a stable, focusable source. 588 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MLL-FN-588: 588 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiments

MLL-FN-588: 588 nm emission determines compatible optics, coatings and detectors for Scientific experiments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instruments

MLL-FN-588: 588 nm emission determines compatible optics, coatings and detectors for Optical instruments. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MLL-FN-588 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · Beam diameter at the aperture (1/e2, mm): <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-FN-588

What cooling does the MLL-FN-588 require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-FN-588 deliver?

Transverse mode: TEM00 · Beam diameter at the aperture (1/e2, mm): <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-FN-588 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-FN-588 (current)MSL-FN-588MSL-W-588
Wavelength588 nm588 nm588 nm
Optical power / pulse energy200-300 mW1~200 mW200-500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00