Back to Home

Power stability, linewidth, beam quality

MLL-III-505-SM505 nm green CW laser

505 nm

MLL-III-505-SM is a 505 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 1~30 mW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-III-505-SM

2 specification rows

Wavelength505 nm
Output / average power1~30 mW
Beam / notesLaser

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 6 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~30 mW
  • Output / average power: 1~50 mW
  • Output / average power: 1~200 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours ± 3°C): <2%, <1%, <0.5%

Beam-quality tolerance context

Nearby series records state M²: <1.1 and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for MLL-III-505-SM; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Collimation

MLL-III-505-SM: Collimation benefits from a stable, focusable source. 505 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Laser medical treatment

MLL-III-505-SM: 505 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Flow cytometry

MLL-III-505-SM: 505 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

DNA sequencing

MLL-III-505-SM: 505 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-III-505-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-III-505-SM (current)TEM-LN-505III-505L
Wavelength505 nm505 nm505 nm
Optical power / pulse energy1~30 mW1~30 mW1~50 mW
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam qualityConfirm for this modelTEM00Confirm for this model