Back to Home

Power stability, linewidth, beam quality

MDL-XS-505505 nm green CW laser

505 nm

MDL-XS-505 is a 505 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Fiber High Stability Green Laser. Key specifications: output / average power 1~50 mW, wavelength (nm) 505±2, operating mode CW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-XS-505

19 specification rows

Output / average power1~50 mW
Beam / notesFiber High Stability Green Laser
Wavelength (nm)505±2
Operating modeCW
Output power after per collimator (mW)≥10
Splitting ratio50:50
Power stability (rms, over 4 hours)<1%
Fiber type1 to 2 SM fiber
Fiber length~1m
Beam diameter after collimator@200mm (mm)0.9±0.05
External diameter of collimator (mm)3.2±0.02
Length of collimator (mm)10mm
Warm-up time (minutes)<5
Operating temperature (℃)10~35
Input voltageDC12V
ModulationTTL + Analog
Expected lifetime (hours)10000
Warranty1 year
Power SupplyAdaptor

Application context

Why this design is used

Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.

Medical imaging

MDL-XS-505: 505 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-XS-505: 505 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-XS-505: 505 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<1%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-XS-505 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: 1 to 2 SM fiber
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (℃): 10~35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam diameter after collimator@200mm (mm): 0.9±0.05
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-XS-505

How is the MDL-XS-505 output delivered?

Fiber type: 1 to 2 SM fiber. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MDL-XS-505 require?

Operating temperature (℃): 10~35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-XS-505 deliver?

Beam diameter after collimator@200mm (mm): 0.9±0.05. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-XS-505 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-XS-505 (current)TEM-LN-505III-505L
Wavelength505 nm505 nm505 nm
Optical power / pulse energy1~50 mW1~30 mW1~50 mW
Operating mode / pulse widthCWCWConfirm for this model
Beam qualityConfirm for this modelTEM00Confirm for this model