Back to Home

Power stability, linewidth, beam quality

MGL-W-589A589 nm yellow CW laser

589 nm

MGL-W-589A is a 589 nm CW laser. Used for collimation, laser medical treatment, scientific experiment, optical instrument. Fan cooling and heat sink. Key specifications: output / average power 1500~7000 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <3%, <2%, (<1% optional). View specifications, datasheet and enquiry options from Precisometer.

Specifications

MGL-W-589A

17 specification rows

Output / average power1500~7000 mW
Beam / notesFan cooling and heat sink
Operating modeCW
Power Stability (rms, 4 hours ± 3°C)<3%, <2%, (<1% optional)
Transverse modeNear TEM00
Beam divergence, full angle (mrad)<2.0
Beam diameter at the aperture (1/e2, mm)~4.0
instrument, etc. Operating temperature (℃)10-35
Power supply (100-240VAC)PSU-W-LED
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz optional; TTL and Analog optiona
Expected lifetime (hours)>10000
Wavelength (nm)589±2
Pointing Stability(urad) (over 2 hours after warm-up and ±3°C)<50
Pointing Stability Over Temperature (urad/°C)<20
Warm-up time (minutes)<10
Beam height from base plate (mm)80
Operating temperature (℃)10-35

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Collimation

MGL-W-589A: Collimation benefits from a stable, focusable source. 589 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (Near TEM00) informs waist size and propagation.

Laser medical treatment

MGL-W-589A: 589 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Scientific experiment

MGL-W-589A: 589 nm emission determines compatible optics, coatings and detectors for Scientific experiment. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

Optical instrument

MGL-W-589A: 589 nm emission determines compatible optics, coatings and detectors for Optical instrument. The catalogued beam parameter (Near TEM00) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect MGL-W-589A to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
instrument, etc. Operating temperature (℃): 10-35 · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <2.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MGL-W-589A

What cooling does the MGL-W-589A require?

instrument, etc. Operating temperature (℃): 10-35 · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MGL-W-589A deliver?

Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <2.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MGL-W-589A with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMGL-W-589A (current)MLL-U-589MLL-FN-589
Wavelength589 nm589 nm589 nm
Optical power / pulse energy1500~7000 mW1~200 mW200-300 mW
Operating mode / pulse widthCWCWCW
Beam qualityNear TEM00TEM00TEM00