Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Fluorescence excitation
MDL-PS-395: 395 nm emission can be matched to the absorption or excitation band used in Fluorescence excitation. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Time resolve spectrum
MDL-PS-395: 395 nm emission sets the excitation and detector-band choice for Time resolve spectrum; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.
Highly sensitive absorption spectroscopy
MDL-PS-395: 395 nm emission sets the excitation and detector-band choice for Highly sensitive absorption spectroscopy; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line. The listed beam characteristic (Near TEM00) also controls focusing and collection geometry.
System integration
Integration and compatibility
Use these checks to connect MDL-PS-395 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Air cooled · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <0.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MDL-PS-395
What cooling does the MDL-PS-395 require?+
Cooled method: Air cooled · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MDL-PS-395 deliver?+
Transverse mode: Near TEM00 · Beam divergence, full angle (mrad): <0.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MDL-PS-395 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.