Medical imaging
MDL-NS-642: 642 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
Pulse energy, repetition rate, pulse width
MDL-NS-642 is a 642 nm Pulsed laser. Used for medical imaging, flow cytometry, dna sequencing, microelectronics. Pulse width 10 ns ~10 ms. Key specifications: operating mode Pulsed, output / average power 1~200 mW. View specifications, datasheet and enquiry options from Precisometer.
Specifications
3 specification rows
| Wavelength | 642 nm |
|---|---|
| Operating mode | Pulsed |
| Output / average power | 1~200 mW |
| Beam / notes | Pulse width 10 ns~10 ms |
Series-level technical context
This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 12 wavelength-near pulsed lasers records; they define the parameters to qualify, but are not substituted for an order-specific datasheet.
Nearby series records state M²: <1.2, Beam divergence, full angle (mrad): <1.0, and Beam divergence, full angle (mrad): ~1.0. These are series context, not guaranteed values for MDL-NS-642; confirm them on the order-specific datasheet.
Application context
Applications named on a datasheet for this product line, interpreted against this model’s listed wavelength and beam data.
MDL-NS-642: 642 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MDL-NS-642: 642 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MDL-NS-642: 642 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.
MDL-NS-642: 642 nm emission determines compatible optics, coatings and detectors for Microelectronics. Beam quality, divergence and pointing stability should be checked against the experiment geometry.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MDL-NS-642 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MDL-NS-642 (current) | MDL-PS-642 | MDL-NS-640 |
|---|---|---|---|
| Wavelength | 642 nm | 642 nm | 640 nm |
| Optical power / pulse energy | 1~200 mW | 1~50 mW | 1~200 mW |
| Operating mode / pulse width | Pulsed | Pulsed | Pulsed |
| Beam quality | Confirm for this model | <1.0 | <1.0 |
Compare the MDL-NS-642 with nearby pulsed lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Photoacoustic imagingConnect optical absorption to wavelength, pulse fluence, stress confinement, acoustic bandwidth, repetition rate, and synchronization at the sample.
Open guide
Ultrafast spectroscopyDesign the pump, probe, delay line, monochromator, visible or SWIR camera, synchronization, and transient-signal budget as one experiment.
Open guide