Back to Home

Fiber output, PM options, seed formats

MDL-III-1273-SM1273 nm infrared fiber laser

1273 nm

MDL-III-1273-SM is a 1273 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing. Fiber output laser High Stability Infrared Laser. Key specifications: output / average power 1~10 mW, operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MDL-III-1273-SM

20 specification rows

Output / average power1~10 mW
Beam / notesFiber output laser High Stability Infrared Laser
Operating modeCW
Power stability (rms, 4 hours ± 3°C)<2%, <1%, <0.5%
Fiber typeSM fiber, PM fiber optional
Fiber Core diameter4-9μm, 0.12NA
Fiber connectorFC/PC, FC/APC optional
Fiber jacketMetal, PVC optional
Transverse modeTEM00
M2 after fiber~1.1
Warm-up time (minutes)<5
Cooled methodConduction
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM
Expected lifetime (hours)>10000
Central wavelength (nm)1273±3
Output power after fiber (mW)1-10
Fiber length1m
Ellipticity>0.95
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MDL-III-1273-SM: 1273 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MDL-III-1273-SM: 1273 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MDL-III-1273-SM: 1273 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MDL-III-1273-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber type: SM fiber, PM fiber optional · Fiber Core diameter: 4-9μm, 0.12NA
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2 after fiber: ~1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MDL-III-1273-SM

How is the MDL-III-1273-SM output delivered?

Fiber type: SM fiber, PM fiber optional · Fiber Core diameter: 4-9μm, 0.12NA. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MDL-III-1273-SM require?

Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MDL-III-1273-SM deliver?

Transverse mode: TEM00 · M2 after fiber: ~1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MDL-III-1273-SM with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMDL-III-1273-SM (current)TEM-F-1273DFBMDL-III-1273DFB-SM
Wavelength1273 nm1273 nm1273 nm
Optical power / pulse energy1~10 mW1~10 mW1~10 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam qualityTEM00Confirm for this modelConfirm for this model