Collimation
MBL-U-491-SF: Collimation benefits from a stable, focusable source. 491 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
Power stability, linewidth, beam quality
MBL-U-491-SF is a 491 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 1~400 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.
Specifications
15 specification rows
| Wavelength | 491 nm |
|---|---|
| Output / average power | 1~400 mW |
| Beam / notes | Laser |
| Operating mode | CW |
| Transverse mode | TEM00 |
| M2 | ~3.0 |
| Polarization ratio | >100:1 |
| Cooled method | Air Cooled/ Water Cooled |
| Warm-up time (minutes) | <10 |
| Power supply (100-240VAC) | PSU-SF |
| Expected lifetime (hours) | >10000 |
| Power stability (rms, 4 hours±3℃) | <3%, <2%, (<1% optional@Water Cooled) |
| M² | ~3.0 |
| Beam diameter at the aperture (1/e2, mm) | ~3.0 |
| Beam divergence (mrad) | <3.0 |
| Beam height from base plate (mm) | 45@Air Cooled/ 61.5@Water Cooled |
Application context
Typical uses for this laser type, with the selection logic tied to the model record.
MBL-U-491-SF: Collimation benefits from a stable, focusable source. 491 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.
MBL-U-491-SF: 491 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
MBL-U-491-SF: 491 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, (<1% optional@Water Cooled)) helps keep measured intensity changes attributable to the sample rather than source drift.
MBL-U-491-SF: 491 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, (<1% optional@Water Cooled)) helps keep measured intensity changes attributable to the sample rather than source drift.
System integration
Use these checks to connect MBL-U-491-SF to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air Cooled/ Water Cooled. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Transverse mode: TEM00 · M2: ~3.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare MBL-U-491-SF with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | MBL-U-491-SF (current) | Long Coherent Length | Low Noise |
|---|---|---|---|
| Wavelength | 491 nm | 488 nm | 488 nm |
| Optical power / pulse energy | 1~400 mW | 1-70 mW | 1-150 mW |
| Operating mode / pulse width | CW | Confirm for this model | Confirm for this model |
| Beam quality | TEM00 | Confirm for this model | TEM 00 |
Compare the MBL-U-491-SF with nearby cw lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
Optical trappingWhy wavelength is decided by photodamage, focal heating, and detector bandwidth rather than trapping force — and what laser noise costs you in piconewtons.
Open guide
Confocal microscopyConnect fluorophores, pinhole size, Airy units, spatial sampling, scan timing, modulation, and power after the fiber in one practical design workflow.
Open guide