Wavelength491 nm
Output / average power1~360 mW

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 2 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~400 mW
  • Output / average power: 1~360 mW
  • Operating mode: CW
  • Power stability (rms, 4 hours±3℃): <3%, <2%, (<1% optional@Water Cooled)

Beam-quality tolerance context

Nearby series records state M²: ~3.0 and Beam divergence (mrad): <3.0. These are series context, not guaranteed values for FC-491; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

FC-491: 491 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

FC-491: Laboratory measurement benefits from a stable, focusable source. 491 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-491 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-491 (current)MBL-U-491-SFMBL-491(FC)
Wavelength491 nm491 nm491 nm
Optical power / pulse energy1~360 mW1~400 mW1~360 mW
Operating mode / pulse widthConfirm for this modelCWConfirm for this model
Beam qualityConfirm for this modelTEM00Confirm for this model