Back to Home

Power stability, linewidth, beam quality

MLL-III-488L488 nm blue CW laser

488 nm

MLL-III-488L is a 488 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Key specifications: output / average power 1-300 mW, optical noise <0.5%, operating mode CW. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MLL-III-488L

19 specification rows

Output / average power1-300 mW
Optical noise<0.5%
Beam / notesSeries: MLL-III-488L
Operating modeCW
Power stability (rms, over 4 hours)<2%, <1%, <0.5%
Transverse modeNear TEM00
M2<2, <1.5
Beam divergence, full angle (mrad)~1.0
Warm-up time (minutes)<5
Operating temperature (°C)10-35
Power supply (100-240VAC)PSU-III-FDA/PSU-III-LED/PSU-A-D/PSU-III-OEM
Expected lifetime (hours)>10000
Central wavelength (nm)488±5
Noise of amplitude (rms, 20Hz-20MHz)<1%, <0.5%
<2, <1.5
Beam diameter at the aperture (1/e2, mm)~3.5, ~1.5
Polarization ratio>50:1, (>100:1 optional) Horizontal±5 degree (Vertical optional)
Beam height from base plate (mm)24.8
Modulation optionDC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Medical imaging

MLL-III-488L: 488 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Flow cytometry

MLL-III-488L: 488 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MLL-III-488L: 488 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MLL-III-488L to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Near TEM00 · M2: <2, <1.5
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MLL-III-488L

What cooling does the MLL-III-488L require?

Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MLL-III-488L deliver?

Transverse mode: Near TEM00 · M2: <2, <1.5. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MLL-III-488L with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMLL-III-488L (current)Long Coherent LengthLow Noise
Wavelength488 nm488 nm488 nm
Optical power / pulse energy1-300 mW1-70 mW1-150 mW
Operating mode / pulse widthCWConfirm for this modelConfirm for this model
Beam qualityNear TEM00Confirm for this modelTEM 00