MLL-III-488-SM is a 488 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Key specifications: operating mode CW, power stability (rms, 4 hours ± 3°c) <2%, <1%, <0.5%, transverse mode Multimode. View specifications, datasheet and enquiry options from Precisometer.
DC-1kHz, 1kHz-10kHz, 10kHz-30kHz, 30kHz-100kHz optional; TTL and Analog optional
Application context
Why this design is used
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
Medical imaging
MLL-III-488-SM: 488 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
MLL-III-488-SM: 488 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
MLL-III-488-SM: 488 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%, <0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.
System integration
Integration and compatibility
Use these checks to connect MLL-III-488-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Thermal management
Cooled method: Conduction · Operating temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: Multimode · Beam divergence, full angle (mrad): ~2.5×1.0
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for MLL-III-488-SM
What cooling does the MLL-III-488-SM require?+
Cooled method: Conduction · Operating temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the MLL-III-488-SM deliver?+
Transverse mode: Multimode · Beam divergence, full angle (mrad): ~2.5×1.0. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare MLL-III-488-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.