Pulse energy, repetition rate, pulse width

HPL-1319-QM1319 nm infrared Q-switched high-power pulsed laser

1319 nm

HPL-1319-QM is a 1319 nm Pulsed laser. Used for marking, carving, measure, science research. Key specifications: operating mode Q-switched, output / average power 50-100 W, repetition rate 10-20 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

HPL-1319-QM

19 specification rows

Operating modeQ-switched
Output / average power50-100 W
Repetition rate10-20 kHz
Pulse width~250 ns
Single pulse energy (mJ)5-10
Ave power stability (rms, 4 hours±3℃)<5%, <3%
Beam divergence, full angle (mrad)<3.5
Warm-up time (minutes)<10
Cooled methodWater Cooled
Operating temperature (℃)15-35
Power supply (220-240AC)PSU-HPL-Q & PSU-HPL-CW*2
Expected lifetime (hours)>10000
Wavelength (nm)1319±1
Average power (W)50-100@10kHz
Pulse duration (ns)~250 @10kHz&100W
Rep. rate10-20 kHz
Peak power (kW)20-40 @10kHz
Beam diameter at the aperture (1/e2,mm)<15
Beam height from base plate (mm)60

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Marking

HPL-1319-QM: Marking depends on how optical energy is delivered to the target; 1319 nm emission governs absorption, while the listed temporal parameter (10-20 kHz) governs peak intensity and heat deposition.

Carving

HPL-1319-QM: 1319 nm emission determines compatible optics, coatings and detectors for Carving. The catalogued beam parameter (<3.5) helps predict how the source will focus and propagate through the instrument.

Measure

HPL-1319-QM: Measure benefits from a stable, focusable source. 1319 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<3.5) informs waist size and propagation.

Science research

HPL-1319-QM: 1319 nm emission determines compatible optics, coatings and detectors for Science research. The catalogued beam parameter (<3.5) helps predict how the source will focus and propagate through the instrument.

System integration

Integration and compatibility

Use these checks to connect HPL-1319-QM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Water Cooled · Operating temperature (℃): 15-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam divergence, full angle (mrad): <3.5 · Beam diameter at the aperture (1/e2,mm): <15
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for HPL-1319-QM

What cooling does the HPL-1319-QM require?

Cooled method: Water Cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the HPL-1319-QM deliver?

Beam divergence, full angle (mrad): <3.5 · Beam diameter at the aperture (1/e2,mm): <15. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare HPL-1319-QM with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterHPL-1319-QM (current)HPL-1319-CWMLL-U-1319-SU
Wavelength1319 nm1319 nm1319 nm
Optical power / pulse energy50-100 W20-50 W1~200 mW
Operating mode / pulse widthQ-switchedCWCW
Beam quality<3.5<3.5TEM00