HPL-1064B-PB1064 nm near-infrared Q-switched high-power pulsed laser

1064 nm

HPL-1064B-PB is a 1064 nm Pulsed laser. Used for dna sequencing, flow cytometry, medical imaging, measurement. Key specifications: operating mode Q-switched, output / average power 10-60 W, repetition rate 0.5 kHz. View specifications, datasheet and enquiry options from Precisometer.

Specifications

HPL-1064B-PB

4 specification rows

Wavelength1064 nm
Operating modeQ-switched
Output / average power10-60 W
Repetition rate0.5 kHz
Pulse width~10 ns

Series-level technical context

Engineering context for a thin Pulsed Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 20 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~10 W
  • Output / average power: 1~25 W
  • Output / average power: 20-30 W
  • Operating mode: Q-switched
  • Operating mode: Mode-locked

Beam-quality tolerance context

Nearby series records state M²: <1.5, Beam divergence, full angle (mrad): <1, Beam divergence, full angle (mrad): <3.5, and Beam divergence, 1/e2 (mrad): <1.5. These are series context, not guaranteed values for HPL-1064B-PB; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Pump and pulsed laser head
  2. Step 2Safety shutter and optional isolator
  3. Step 3Beam-expansion or focusing optics
  4. Step 4Sample with synchronized trigger or detector

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

DNA sequencing

HPL-1064B-PB: 1064 nm emission can be matched to the absorption or excitation band used in DNA sequencing. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Flow cytometry

HPL-1064B-PB: 1064 nm emission can be matched to the absorption or excitation band used in Flow cytometry. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Medical imaging

HPL-1064B-PB: 1064 nm emission can be matched to the absorption or excitation band used in Medical imaging. Power stability and beam pointing should be confirmed because both affect quantitative image or fluorescence intensity.

Measurement

HPL-1064B-PB: Measurement benefits from a stable, focusable source. 1064 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare HPL-1064B-PB with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterHPL-1064B-PB (current)HPL-1064-CWTEM-LN-1064
Wavelength1064 nm1064 nm1064 nm
Optical power / pulse energy10-60 W50-100 W1~500 mW
Operating mode / pulse widthQ-switchedCWConfirm for this model
Beam qualityConfirm for this model<8Confirm for this model