FL-631-SLM631 nm red single-frequency low-noise fiber laser
631 nm
FL-631-SLM is a 631 nm Fiber laser. Used for medical imaging, flow cytometry, dna sequencing, scientific research. Laser. Key specifications: output / average power 1~1500 mW, operating mode CW, free space output power (mw) 1mW-1.5W. View specifications, datasheet and enquiry options from Precisometer.
Typical uses for this laser type, with the selection logic tied to the model record.
Medical imaging
FL-631-SLM: 631 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Flow cytometry
FL-631-SLM: 631 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
DNA sequencing
FL-631-SLM: 631 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.
Scientific research
FL-631-SLM: 631 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.
System integration
Integration and compatibility
Use these checks to connect FL-631-SLM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Fiber delivery interface
Fiber connector: FC/APC
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Cooled method: Air cooled or Water cooled · Operating temperature (℃): 15-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Technical FAQ
Integration questions for FL-631-SLM
How is the FL-631-SLM output delivered?+
Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
What cooling does the FL-631-SLM require?+
Cooled method: Air cooled or Water cooled · Operating temperature (℃): 15-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
What beam does the FL-631-SLM deliver?+
Transverse mode: TEM00 · M2: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Need this configured?
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Compare FL-631-SLM with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.