Scientific research
FL-343-Pico: 343 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<2) helps predict how the source will focus and propagate through the instrument.
Fiber output, PM options, seed formats
FL-343-Pico is a 343 nm Fiber laser. Used for scientific research, laser processing. Pulse width 10-900ps fixed. Key specifications: operating mode Pulsed, output / average power 1~50 mW, power stability (rms, 4 hours, ±3℃) <5%,<3%. View specifications, datasheet and enquiry options from Precisometer.
Specifications
19 specification rows
| Operating mode | Pulsed |
|---|---|
| Output / average power | 1~50 mW |
| Beam / notes | Pulse width 10-900 ps fixed |
| Power stability (rms, 4 hours, ±3℃) | <5%,<3% |
| Pulse duration (ps) | 100-900 |
| M2 | <2 |
| Rep. rate | 100kHz-20MHz |
| Polarization ratio (dB) | >15 Horizontal (Vertical optional) |
| Warm-up time (minutes) | <15 |
| Delivery fiber length(cm) | 60 |
| Cooled method | Air cooled |
| Operating temperature (℃) | 15-35 |
| Operating voltage (VDC) | 12V/11.5A |
| Expected lifetime (hours) | >10000 |
| Fundamental Frequency | Third harmonic |
| Wavelength (nm) | 343±1 |
| Average power(mW) | 1-50@5MHz |
| M² | <2 |
| Beam height from base plate (mm) | 40 |
Application context
Applications named on this model’s datasheet, expanded with the model’s optical specifications.
FL-343-Pico: 343 nm emission determines compatible optics, coatings and detectors for Scientific research. The catalogued beam parameter (<2) helps predict how the source will focus and propagate through the instrument.
FL-343-Pico: Laser processing depends on how optical energy is delivered to the target; 343 nm emission governs absorption, while the listed temporal parameter (100-900) governs peak intensity and heat deposition.
System integration
Use these checks to connect FL-343-Pico to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Cooled method: Air cooled · Operating temperature (℃): 15-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
M2: <2 · Polarization ratio (dB): >15 Horizontal (Vertical optional). Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.
Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.
Model selection
Compare FL-343-Pico with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | FL-343-Pico (current) | FL-343-PS | FL-343-Nano |
|---|---|---|---|
| Wavelength | 343 nm | 343 nm | 343 nm |
| Optical power / pulse energy | 1~50 mW | 1~50 mW | 10~300 mW |
| Operating mode / pulse width | Pulsed | Pulsed | Pulsed |
| Beam quality | <2 | <2 | <2 |
Compare the FL-343-Pico with nearby fiber lasers across the wavelength range.
Choosing a laser
Which specifications decide the experiment, and which ones cost money without changing the result.
PhotonicsLinewidth, spectral width, RIN, M², and coherence length answer five different questions. Translate each into the units your experiment is designed in — and learn which ones not to pay for.
Open guide
PhotonicsSingle-mode fiber does not preserve polarization. Pin the state, erase it with a scrambler, or maintain it in PM fiber — which one your measurement needs, and the response time and extinction ratio that decide it.
Open guide