Back to Home

Power stability, linewidth, beam quality

FC-OEM-488488 nm blue CW laser

488 nm

FC-OEM-488 is a 488 nm CW laser. Used for medical imaging, flow cytometry, dna sequencing. Fiber core diameter: 4-9 μm; M²: 1.1. Key specifications: output / average power 150 mW, power stability <2%, <1%, <0.5%, m² 1.1. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-OEM-488

19 specification rows

Output / average power150 mW
Power stability<2%, <1%, <0.5%
1.1
Beam / notesFiber core diameter: 4-9 um
Operating modeCW
Fiber typeSM fiber, PM fiber optional
Fiber Core diameter4-9μm, 0.12NA
Fiber connectorFC/PC, FC/APC optional
Fiber length0.8m
Fiber jacket0.9mm PVC
Warm-up time (minutes)<5
Cooled methodConduction
Operating temperature (°C)10-35
Operating voltage (VDC)5V
Expected lifetime (hours)>10000
Central wavelength (nm)488±10
Transverse modeTEM00
Ellipticity>0.95
M2 after fiber~1.1

Applications

Uses named on this model’s datasheet.

  • Medical imaging
  • Flow cytometry
  • DNA sequencing

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.