Back to Home

Power stability, linewidth, beam quality

FC-OEM -410410 nm violet CW laser

410 nm

FC-OEM -410 is a 410 nm CW laser. Used for flow cytometry, dna sequencing, medical imaging, spectrum analysis. Features: Integrated optoelectronic. Key specifications: output / average power 1~40 mW, power stability <0.5%, features Integrated optoelectronic. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-OEM -410

4 specification rows

Wavelength410 nm
Output / average power1~40 mW
Power stability<0.5%
Beam / notesFeatures: Integrated optoelectronic
FeaturesIntegrated optoelectronic

Series-level technical context

Engineering context for a thin CW Lasers record

This model has no standalone PDF and only a small number of model-specific rows. The values below are traceable context from 11 nearby configurations on the same source-product record; they define the parameters to qualify, but are not substituted for an order-specific datasheet.

Typical operating fields in the series

  • Output / average power: 1~50 mW
  • Output / average power: 1~30 mW
  • Output / average power: 1~40 mW
  • Operating mode: CW
  • Power stability: <1%

Beam-quality tolerance context

Nearby series records state M²: <1.1, Beam divergence, full angle (mrad): <1.0, Beam divergence, full angle (mrad): ~2.5×0.2, and Beam divergence, full angle (mrad): <1.5. These are series context, not guaranteed values for FC-OEM -410; confirm them on the order-specific datasheet.

Optical integration schematic

  1. Step 1Laser head and temperature-stabilized base
  2. Step 2Safety shutter and optional optical isolator
  3. Step 3Beam steering, expansion or fiber-launch optics
  4. Step 4Experiment input with wavelength-matched coatings

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Flow cytometry

FC-OEM -410: 410 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

FC-OEM -410: 410 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Medical imaging

FC-OEM -410: 410 nm emission can be matched to the absorption or excitation band used in Medical imaging. The stated stability or noise figure (<0.5%) helps keep measured intensity changes attributable to the sample rather than source drift.

Spectrum analysis

FC-OEM -410: 410 nm emission sets the excitation and detector-band choice for Spectrum analysis; linewidth and wavelength stability determine how cleanly weak spectral features can be separated from the laser line.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-OEM -410 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-OEM -410 (current)MDL-C-410TUN-403~406 Wavelength tunable
Wavelength410 nm410 nm410 nm
Optical power / pulse energy1~40 mW1~50 mW1~30 mW
Operating mode / pulse widthConfirm for this modelConfirm for this modelCW
Beam qualityConfirm for this modelConfirm for this modelNear TEM00