Back to Home

Power stability, linewidth, beam quality

FC-522522 nm green CW laser

522 nm

FC-522 is a 522 nm CW laser. Key specifications: output / average power 1~6000 mW, operating mode CW, power stability (rms, over 4 hours) <1%, <2%, <3%, <5%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

FC-522

16 specification rows

Output / average power1~6000 mW
Operating modeCW
Power stability (rms, over 4 hours)<1%, <2%, <3%, <5%
Fiber NA0.22
Fiber ConnectorSMA905
Fiber Length (m)1 (Other lengths are available on request)
Warm-up time (minutes)<5
Operating temperature (℃)10~35
Cooling wayBy air
Expected lifetime (hours)10000
Warranty1 year
Wavelength (nm)522±1
Output power after fiber (mW)>1,10, 20 …, 720
Fiber Core Diameter (μm)400/ 200 (MM fiber, other fiber core diameter are available on request)
Input power100-240VAC
Modulation optionalTTL on/off, 1Hz- 1kHz, 1kHz- 10kHz, 10kHz-30kHz; and Analog modulation optional.

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

FC-522: 522 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. Beam quality, divergence and pointing stability should be checked against the experiment geometry.

Laboratory measurement

FC-522: Laboratory measurement benefits from a stable, focusable source. 522 nm emission fixes the compatible coatings and detector response, while M², divergence and pointing stability should be confirmed for the intended beam path.

System integration

Integration and compatibility

Use these checks to connect FC-522 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber NA: 0.22 · Fiber Connector: SMA905
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating temperature (℃): 10~35 · Cooling way: By air
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Technical FAQ

Integration questions for FC-522

How is the FC-522 output delivered?

Fiber NA: 0.22 · Fiber Connector: SMA905. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the FC-522 require?

Operating temperature (℃): 10~35 · Cooling way: By air. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare FC-522 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterFC-522 (current)MSL-FN-522MSL-R-522
Wavelength522 nm522 nm522 nm
Optical power / pulse energy1~6000 mW1~150 mW150~500 mW
Operating mode / pulse widthCWCWCW
Beam qualityConfirm for this modelTEM00TEM00