Back to Home

Power stability, linewidth, beam quality

MSL-R-522522 nm green CW laser

522 nm

MSL-R-522 is a 522 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 150~500 mW, operating mode CW, transverse mode TEM00. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MSL-R-522

14 specification rows

Wavelength522 nm
Output / average power150~500 mW
Beam / notesLaser
Operating modeCW
Transverse modeTEM00
Longitudinal modeSingle
Spectral line width (nm)<5MHz
Pointing stability over temperature (μrad/°C)<8
Warm-up time (minutes)<15
Cooled method (water cooled)WCH-580
Operating temperature (°C)20-30
Power supply (100-240VAC)PSU-W-FDA
Expected lifetime (hours)>10000
Pointing stability(μrad) (over 2 hours after warm-up and ±3°C)<50
Coherent length (m)>50

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Collimation

MSL-R-522: Collimation benefits from a stable, focusable source. 522 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MSL-R-522: 522 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Flow cytometry

MSL-R-522: 522 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<8) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MSL-R-522: 522 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<8) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MSL-R-522 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MSL-R-522

What cooling does the MSL-R-522 require?

Cooled method (water cooled): WCH-580 · Operating temperature (°C): 20-30. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MSL-R-522 deliver?

Transverse mode: TEM00. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MSL-R-522 with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMSL-R-522 (current)MSL-FN-522TUN-518-522
Wavelength522 nm522 nm522 nm
Optical power / pulse energy150~500 mW1~150 mW1~30 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00<1.0