Back to Home

Power stability, linewidth, beam quality

MGL-FN-522-SM522 nm green CW laser

522 nm

MGL-FN-522-SM is a 522 nm CW laser. Used for collimation, laser medical treatment, flow cytometry, dna sequencing. Laser. Key specifications: output / average power 1~300 mW, operating mode CW, power stability (rms, 4 hours±3℃) <3%, <2%, <1%. View specifications, datasheet and enquiry options from Precisometer.

Specifications

MGL-FN-522-SM

18 specification rows

Output / average power1~300 mW
Beam / notesLaser
Operating modeCW
Power stability (rms, 4 hours±3℃)<3%, <2%, <1%
Transverse modeTEM00
M2<1.2
Fiber connectorFC/APC
Fiber jacketPVC
Fiber length1m
Warm-up time (minutes)<10
Operating Temperature (°C)10-35
Power supply (100-240VAC)PSU-H-FDA/ PSU-H-LED/ PSU-SR
Expected lifetime (hours)>10000
Wavelength (nm)522±1
Output power (mW)1-300
<1.2
Polarizaiton (optional)>50:1 after PM fiber
Modulation optionDC-1kHz; TTL and Analog optional

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Collimation

MGL-FN-522-SM: Collimation benefits from a stable, focusable source. 522 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (TEM00) informs waist size and propagation.

Laser medical treatment

MGL-FN-522-SM: 522 nm emission determines compatible optics, coatings and detectors for Laser medical treatment. The catalogued beam parameter (TEM00) helps predict how the source will focus and propagate through the instrument.

Flow cytometry

MGL-FN-522-SM: 522 nm emission can be matched to the absorption or excitation band used in Flow cytometry. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

DNA sequencing

MGL-FN-522-SM: 522 nm emission can be matched to the absorption or excitation band used in DNA sequencing. The stated stability or noise figure (<3%, <2%, <1%) helps keep measured intensity changes attributable to the sample rather than source drift.

System integration

Integration and compatibility

Use these checks to connect MGL-FN-522-SM to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Fiber delivery interface
Fiber connector: FC/APC
Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.
Thermal management
Operating Temperature (°C): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Transverse mode: TEM00 · M2: <1.2
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for MGL-FN-522-SM

How is the MGL-FN-522-SM output delivered?

Fiber connector: FC/APC. Match the listed connector and fiber mode exactly; SMA905, FC/PC and FC/APC are not interchangeable, and a single-mode launch requires mode-field as well as numerical-aperture matching.

What cooling does the MGL-FN-522-SM require?

Operating Temperature (°C): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the MGL-FN-522-SM deliver?

Transverse mode: TEM00 · M2: <1.2. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare MGL-FN-522-SM with the closest available models in the CW Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterMGL-FN-522-SM (current)MSL-FN-522MSL-R-522
Wavelength522 nm522 nm522 nm
Optical power / pulse energy1~300 mW1~150 mW150~500 mW
Operating mode / pulse widthCWCWCW
Beam qualityTEM00TEM00TEM00