Back to Home

Pulse energy, repetition rate, pulse width

AO-K-280&295280 nm deep-UV Q-switched pulsed laser

280 nm

AO-K-280&295 is a 280 nm Pulsed laser. Q-switched UV Laser. Key specifications: operating mode Q-switched, output / average power 100 mW& 100 mW, pulse energy 20 uJ& 20 uJ. View specifications, datasheet and enquiry options from Precisometer.

Specifications

AO-K-280&295

18 specification rows

Wavelength280 nm
Operating modeQ-switched
Output / average power100 mW& 100 mW
Pulse energy20 uJ& 20 uJ
Beam / notesQ-switched UV Laser
Ave power stability (over 4 hours)<5%,<3%, <2%
Beam diameter at the aperture (1/e2, mm)~1
Polarization ratio>100:1 Horizontal
Warm-up time (minutes)<10
Cooled methodAir cooled
Operating temperature (℃)10-35
Operating voltage (VDC)24V/42A
Expected lifetime (hours)>10000
Single pulse energy (uJ)>20@5kHz
Rep. rate5-10kHz
Pulse duration (ns)<10@5kHz
Peak power (kW)~4@5kHz
Beam divergence, full angle (mrad)<3.5
Beam height from base plate (mm)116.5

Application context

Why this design is used

Typical uses for this laser type, with the selection logic tied to the model record.

Optical instrumentation

AO-K-280&295: 280 nm emission determines compatible optics, coatings and detectors for Optical instrumentation. The catalogued beam parameter (<3.5) helps predict how the source will focus and propagate through the instrument.

Laboratory measurement

AO-K-280&295: Laboratory measurement benefits from a stable, focusable source. 280 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<3.5) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect AO-K-280&295 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Thermal management
Cooled method: Air cooled · Operating temperature (℃): 10-35
Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.
Beam parameters at the output
Beam diameter at the aperture (1/e2, mm): ~1 · Polarization ratio: >100:1 Horizontal
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for AO-K-280&295

What cooling does the AO-K-280&295 require?

Cooled method: Air cooled · Operating temperature (℃): 10-35. Provide the stated cooling method and keep the laser-head base thermally coupled; temperature drift moves wavelength, output power and beam pointing.

What beam does the AO-K-280&295 deliver?

Beam diameter at the aperture (1/e2, mm): ~1 · Polarization ratio: >100:1 Horizontal. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare AO-K-280&295 with the closest available models in the Pulsed Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterAO-K-280&295 (current)PS-L-280PS-M-280
Wavelength280 nm280 nm280 nm
Optical power / pulse energy100 mW& 100 mW1~10 mW1~40 mW
Operating mode / pulse widthQ-switched<500Passively Q-switched
Beam quality<3.5<10<1