Back to Home

Fiber output, PM options, seed formats

10271027 nm near-infrared narrow-linewidth low-noise fiber laser

1027 nm

1027 is a 1027 nm Fiber laser. Used for optical microscope, photon imaging, physics experiment. M²: <1.1. Key specifications: output / average power 1~10 W, spectral linewidth <10 kHz, optical noise <0.05% RIN(DC-3 MHz). View specifications, datasheet and enquiry options from Precisometer.

Specifications

1027

4 specification rows

Wavelength1027 nm
Output / average power1~10 W
Spectral linewidth<10 kHz
Optical noise<0.05% RIN(DC-3 MHz)
<1.1

Application context

Why this design is used

Applications named on this model’s datasheet, expanded with the model’s optical specifications.

Optical microscope

1027: 1027 nm emission can be matched to the absorption or excitation band used in Optical microscope. The stated stability or noise figure (<0.05% RIN(DC-3 MHz)) helps keep measured intensity changes attributable to the sample rather than source drift.

Photon imaging

1027: 1027 nm emission can be matched to the absorption or excitation band used in Photon imaging. The stated stability or noise figure (<0.05% RIN(DC-3 MHz)) helps keep measured intensity changes attributable to the sample rather than source drift.

Physics experiment

1027: Physics experiment benefits from a stable, focusable source. 1027 nm emission fixes the compatible coatings and detector response, while the listed beam characteristic (<1.1) informs waist size and propagation.

System integration

Integration and compatibility

Use these checks to connect 1027 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Beam parameters at the output
M²: <1.1
Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Technical FAQ

Integration questions for 1027

What beam does the 1027 deliver?

M²: <1.1. Size the downstream optics from the stated beam diameter and divergence rather than from the aperture of the housing, and confirm the polarisation state before specifying isolators or polarising optics.

Need this configured?

Share wavelength, operating mode, output power or pulse energy, linewidth or pulse width, delivery, control, and safety requirements and we will qualify the matching configuration and lead time.

Open laser selector

Model selection

Nearby series comparison

Compare 1027 with the closest available models in the Fiber Lasers family. Confirm option-dependent values on the final configuration before ordering.

Selection parameter1027 (current)FL-1027-SLMFL-1027-LN-L
Wavelength1027 nm1027 nm1027 nm
Optical power / pulse energy1~10 W1~10 W1~10 W
Operating mode / pulse widthConfirm for this modelCWCW
Beam quality<1.1TEM00TEM00