Back to Home
Measurement & Safety

CN0310VIS-M2-B

Automatic M² Beam-Quality Measurement

  • Model: CN0310VIS-M2-B
  • Product: Automatic beam-quality analyser
  • Detection wavelength: 340-1100 nm
  • M² range: 1-50
  • Laser repetition rate: 20 Hz to CW
  • Minimum input beam diameter (1/e²): ≥1.0 mm at 355 nm; ≥1.2 mm at 532 nm; ≥1.6 mm at 1064 nm
Automatic M² Beam-Quality Measurement

How the measurement works

Initialise the measurement parameters, select the lens and attenuation, then acquire profiles along the propagation axis. Software fits the beam evolution to report the beam-quality parameters.

Features

  • 340-1100 nm detection
  • CW and pulsed operation from 20 Hz repetition rate
  • Automatic OD selection
  • 200 mm double-optical-path travel
  • USB 3.0 sensor and dual-axis RS232 controller

Applications

  • Laser beam-quality analysis
  • Focusing and process development
  • Laser, fibre-optic and optical research

Technical specifications

System performance

ParameterSpecification
ModelCN0310VIS-M2-B
ProductAutomatic beam-quality analyser
Detection wavelength340-1100 nm
M² range1-50
Laser repetition rate20 Hz to CW
Minimum input beam diameter (1/e²)≥1.0 mm at 355 nm; ≥1.2 mm at 532 nm; ≥1.6 mm at 1064 nm
Maximum input beam diameter (1/e²)≤7.0 mm at 355 nm; ≤10.0 mm at 532 nm; ≤16.0 mm at 1064 nm
Detection accuracy<3%
Focal-position accuracy±10%
Maximum input power<1 W
Detection modeAutomatic after parameter initialisation
Typical detection time≤60 s excluding initialisation
Weight<15 kg
Dimensions, L × W × H467.37 × 130 × 177.56 mm, excluding feet
Operating environment15-40 °C; relative humidity <60%; clean environment

Sensor module

ParameterSpecification
SensorCN0310VIS-B
Pixel size3.2 μm
Resolution2448 × 2448 pixels
Response band340-1100 nm
Sensitive area7.8 × 7.8 mm
Bit depth12-bit
Sensor spot range0.03-5 mm, TEM00
InterfaceUSB 3.0

Motion, attenuation and optics

ParameterSpecification
Travel200 mm, double optical path
Repeat positioning accuracy±5 μm
ControllerRS232; dual-axis
Stage5-phase stepper with cross-roller guide
Power supply24 V, 2 A
Attenuator maximum input diameter16.0 mm at 1/e²
Attenuation settingsOD0.5 / OD1 / OD1.5 / OD2 / OD3, automatic switching
Standard lens focal lengthsF200 / F350 / F500
Lens effective clear aperture<17 mm
Wavefront distortion<λ/10 at 1064 nm

Software and computer

ParameterSpecification
Operating systemWindows 10 / 11, 64-bit
Office softwareWPS Office pre-installed
RAM≥8 GB
Processor≥2.5 GHz; ≥4 cores; Intel i5 or equivalent recommended
Recommended display1920 × 1080

Technical figures

CN0310VIS-M2-B mechanical outline
CN0310VIS-M2-B mechanical outline
CN0310VIS-M2-B software and analysis example (illustrative)
CN0310VIS-M2-B software and analysis example (illustrative)

Construction details

  • Detector assembly: CN0310VIS-B.
Product datasheet (PDF)

Configure your measurement

Include these details with your enquiry so we can match the instrument and accessories.

  • Wavelength, repetition rate and pulse parameters
  • Input power and 1/e² beam diameter
  • Expected waist, lens choice, scan range and computer configuration
Explore all 20 measurement & safety categories