Receiver calibration
Variable Attenuator: Known, repeatable attenuation creates controlled optical levels for linearity, sensitivity and dynamic-range measurements.

Laser components & accessories
provides 4 kinds of variable attenuators for different application. The circular variable attenuator can make the optical density linearly varies around a 0 ° -270 ° circle for measuring laser energy farthest. As for the square one, the optical density linearly varies across the length for measuring laser energy. Also the high power variable attenuator is available for customization. Applications: Detector of photon
| Model | VA-C |
|---|---|
| Material | BK7grade A optical glass, Fused silica |
| Optical Density Range | OD0-OD3 |
| Outside Diameter | Φ54mm±0.25 |
| Dimension | 54*42*67mm |
| Linearity of Density | ±5%@632.8nm |
| Coating | S1:Ni-Cr-Fe; S2:Boardband AR coating; incidence angle:0°-15° |
| Clear aperture | >80% diameter |
| Damage threshold | 30W/cm 2 CW |
| Active wavelength | 400-1100 nm |
| Applicable power | <1000 mW |
| Model | VA-S |
|---|---|
| Material | BK7grade A optical glass, Fused silica |
| Optical Density Range | OD0-OD2 |
| Dimension | 76.2*25.4*2.0mm |
| Linearity of Density | OD±5% |
| Coating | S1:Ni-Cr-Fe; S2:Boardband AR coating; incidence angle:0°-15° |
| Clear aperture | >80% diameter |
| Damage threshold | 30W/cm 2 CW |
| Active wavelength | 400-1100 nm |
| Model | VA-P |
|---|---|
| Dimensions | Φ33 mm ×65 (L) mm |
| Wavelength | 400-1100 nm (Other wavelengths can be customized) |
| Model | ATT-45 | ATT-20 |
|---|---|---|
| Attenuation wavelength | 1.064 μm | |
| Limiting aperture | ≤ 5mm | |
| Polarization state | Suitable for P polarization | |
| Dynamic adjustment range | 0~ 4 5 dB (customizable) | 0~20 dB (customizable) |
| Step width | ≤ 1 dB | |
| Control precision | better than 0.5dB | better than 1dB |
| Damage threshold | ≥2J/cm 2 | ≥2J/cm 2 @20ns |
| Fastest adjustment speed | ≥ 3 dB/s | ≥ 1 dB/s |
| I nsertion loss | 10% | |
| Communication interface | RS 232/ 422 /485 | RS 232 |
| Power supply | DC 24V |
Application context
Application fit depends on the ordered configuration; catalog values are separated from fields that still require confirmation.
Variable Attenuator: Known, repeatable attenuation creates controlled optical levels for linearity, sensitivity and dynamic-range measurements.
Variable Attenuator: Response time and control range determine whether the component can suppress source fluctuations without saturating the actuator.
Engineering reference
Variable Attenuator is a configurable optical attenuation or power-control component in the Laser components and accessories family. The final part number should be released only after the optical, mechanical, electrical and environmental fields below are matched to the intended instrument.
An optical attenuator or regulator controls transmitted power without changing the rest of the link. The useful configuration is set by wavelength, attenuation range, residual insertion loss, response time and whether control is manual, electrical or closed-loop.
Selection guidance describes the engineering fields that must be checked. It does not assign an option-dependent value that is absent from the catalog record.
Technical FAQ
Confirm wavelength and fiber, attenuation range, accuracy and repeatability, response behavior, power handling, and control interface. These fields are coupled, so the final part number should be checked against the complete instrument rather than selected from the model name alone.
An optical attenuator or regulator controls transmitted power without changing the rest of the link. The useful configuration is set by wavelength, attenuation range, residual insertion loss, response time and whether control is manual, electrical or closed-loop. Freeze the optical, mechanical and electrical interfaces before releasing the surrounding assembly.
Approve the configuration-specific specification, mechanical drawing, connector or pinout definition, environmental suffix and acceptance-test limits supplied with the quotation. Any field absent from the local record remains a confirmation item, not an assumed capability.