IUA4100KPA(NIR) Industrial Camera/Analytical Imaging with Sony IMX464LQR sensor, 4.1MP (2688×1520) for professional imaging.

Sensor
Sony IMX464LQR
Resolution
4.1MP (2688×1520)
Pixel Size
2.9 µm × 2.9 µm
Frame Rate
90 fps @ 2688×1520
Interface
USB3.0 (USB3.1 GEN1)
IUA4100KPA(NIR)

Application context

Why this design is used

Scientific imaging

IUA4100KPA(NIR): The Sony IMX464LQR sensor, 4.1MP (2688×1520) resolution, and 2.9 µm × 2.9 µm pixels defines the sensitivity, sampling and field coverage available for Scientific imaging. The 90 fps @ 2688×1520 frame-rate listing also sets the fastest full-frame acquisition regime.

Instrument integration

IUA4100KPA(NIR): The Sony IMX464LQR sensor, 4.1MP (2688×1520) resolution, and 2.9 µm × 2.9 µm pixels defines the sensitivity, sampling and field coverage available for Instrument integration. The 90 fps @ 2688×1520 frame-rate listing also sets the fastest full-frame acquisition regime.

Specifications

IUA4100KPA(NIR)

22 specification rows

The IUA4100KPA(NIR) is an industrial & analytical camera in the IUA series, built around a Sony IMX464LQR sensor, 4.1MP (2688×1520) resolution, 2.9 µm × 2.9 µm pixels, frame rates up to 90 fps @ 2688×1520, a USB3.0 (USB3.1 GEN1) interface. It suits industrial camera/analytical imaging where reliable imaging performance and interface compatibility matter.

Key Parameters

ModelIUA4100KPA(NIR)
SensorSony IMX464LQR
Effective Pixels / Resolution4.1MP (2688×1520)
Frame Rate (Full Resolution)90 fps @ 2688×1520
Shutter TypeRolling shutter
Color TypeColor(NIR)

Imaging Performance

Pixel Size2.9 µm × 2.9 µm
Sensor Size7.8 mm × 4.41 mm
Diagonal1/1.8" (8.96 mm)
Dynamic Range72 dB
Bit Depth8/12-bit
Sensitivity2376 mV

Interface & Mechanical

Data InterfaceUSB3.0 (USB3.1 GEN1)
GPIO1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output
Lens MountC-mount
Dimensions68 mm × 68 mm × 28.1 mm
Weight228g
Power SupplyUSB3.0 interface power / DC 12 V power

Environment & Certification

Operating Temperature / Humidity10 °C ~ +50 °C / 20%~80% non-condensing
Storage Temperature / Humidity30 °C ~ +70 °C / Available on request
Operating SystemWindows 32-bit/Windows RT/Linux/macOS/Android; x86/x64/ARM HF/ARM EL/ARM64
CertificationCE, FCC

System integration

Integration and compatibility

Use these checks to connect IUA4100KPA(NIR) to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Lens and microscope interface
Lens Mount: C-mount
Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.
Sensor and sampling
Sensor: Sony IMX464LQR · Resolution: 4.1MP (2688×1520)
Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.
Interface and data rate
Frame Rate: 90 fps @ 2688×1520 · Interface: USB3.0 (USB3.1 GEN1)
Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.
Hardware synchronization
GPIO: 1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output
Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.
Cooling and noise floor
Dynamic Range: 72 dB
Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Technical FAQ

Integration questions for IUA4100KPA(NIR)

What lens mount is required for the IUA4100KPA(NIR)?

Lens Mount: C-mount. Use a lens image circle that covers the sensor and check flange distance before adding C/CS, F-mount or M42 adapters.

What sensor and pixel pitch does the IUA4100KPA(NIR) use?

Sensor: Sony IMX464LQR · Resolution: 4.1MP (2688×1520). Match pixel pitch to the diffraction-limited spot the optics deliver. Sampling finer than the optics resolve multiplies data volume without adding information; sampling coarser discards resolution you have paid for.

How does the IUA4100KPA(NIR) connect to the acquisition computer?

Frame Rate: 90 fps @ 2688×1520 · Interface: USB3.0 (USB3.1 GEN1). Confirm the host can sustain the interface bandwidth continuously, not in burst. A camera that outruns the write path stalls acquisition rather than dropping quietly to a lower rate.

Does the IUA4100KPA(NIR) support hardware triggering?

GPIO: 1 optically isolated input, 1 optically isolated output, 2 non-isolated input/output. Confirm edge polarity, pulse-width limits and whether each line is opto-isolated before connecting TTL or GPIO signals. A software exposure command is not equivalent to a hardware trigger.

What is the noise performance of the IUA4100KPA(NIR)?

Dynamic Range: 72 dB. Judge these figures at the exposure time you will actually use. Cooling matters where dark current accumulates over seconds; read noise dominates short exposures where it never does.

Need help choosing?

Tell us your sensor, resolution, spectral range, frame-rate, interface, and software requirements and we will confirm the matching configuration and lead time.

Open camera finder

Model selection

Nearby series comparison

Compare IUA4100KPA(NIR) with the closest available models in the IUA family. Confirm option-dependent values on the final configuration before ordering.

Selection parameterIUA4100KPA(NIR) (current)IUA390KMAIUA4200KMA-10G
SensorSony IMX464LQRSony IMX287LLRGSENSE2020e
Resolution4.1MP (2688×1520)0.39MP (720×540)4.2MP (2048×2048)
Sensor size7.8 mm × 4.41 mm4.97 mm × 3.73 mm13.31 mm × 13.31 mm
Pixel size / frame rate2.9 µm × 2.9 µm6.9 µm × 6.9 µm6.5 µm × 6.5 µm