Spectroscopy Detectors · Scientific spectral CCD
DField-VS-A4
DField-VS-A4 TE-Cooled CCD
- Active pixels: 2048 × 264
- Pixel size: 15 × 15 µm
- Image area: 30.7 × 3.96 mm
- Peak quantum efficiency: 95% at 800 nm
- Digitization: 16 bit
- Maximum integration time: 60 min
Product range
Where DField-VS-A4 fits
- Category: Spectroscopy Detectors
- Family: Scientific spectral CCD
Specifications
| Active pixels | 2048 × 264 |
|---|---|
| Pixel size | 15 × 15 µm |
| Image area | 30.7 × 3.96 mm |
| Peak quantum efficiency | 95% at 800 nm |
| Digitization | 16 bit |
| Maximum integration time | 60 min |
| Trigger | Internal or external TTL |
| Communication | USB 2.0 |
| Power | 12 V DC, < 50 W |
Product comparison
Check a reference product
Considering DField-VS-A4 for an existing setup? Send us the reference product number and your required specifications. Our engineers can help check the function, configuration, dimensions and interfaces.
Ask our engineers →Complete source specification
Model-by-model comparison
The full manufacturer-published comparison is transcribed below so model differences remain visible rather than being reduced to a single range.
| Parameter | DField-VS-A4 |
|---|---|
| Active pixels (W × H) | 2048 × 264 |
| Pixel size (W × H) | 15 × 15 µm |
| Image area (W × H) | 30.7 × 3.96 mm |
| Read noise at 500 kHz | < 8 e⁻; < 5 e⁻ typical |
| Peak quantum efficiency | 95% at 800 nm |
| Active-pixel full-well depth | > 90 ke⁻ |
| Dark current | < 0.1 e⁻/pixel/s |
| Power supply | < 50 W, 12 V DC |
| Maximum integration time | 60 min |
| Trigger mode | Internal or external TTL |
| Communication port | USB 2.0 |
| Operating temperature | −20 to +55 °C |
| Storage temperature | −40 to +70 °C |
| Digitization | 16 bit |
Design and integration details
- Deep cooling specified at −60 °C with a 25 °C ambient temperature.
- 30.7 mm-wide sensor captures a broad spectral band in one acquisition.
- Low read noise and dark current for weak-light spectroscopy.
- Internal or external TTL triggering with USB 2.0 communication.
Application and connection notes
- Designed as a spectrograph detector head for Raman, fluorescence and photoluminescence acquisition.
- The archived source includes the quantum-efficiency curve and CCD mechanical configuration in the product gallery.
Values are transcribed from the archived product table and diagrams. Confirm the final detector, electronics and spectrograph interface for your configuration.
System integration
Integration and compatibility
- Spectral response: Peak quantum efficiency: 95% at 800 nm
- Active area: Active pixels: 2048 × 264 · Pixel size: 15 × 15 µm
Technical FAQ
Integration questions for DField-VS-A4
What wavelengths does the DField-VS-A4 detect?
- Peak quantum efficiency: 95% at 800 nm. Responsivity varies strongly across the stated band. Read the figure at your own wavelength rather than at the peak the headline range implies.
What is the active area of the DField-VS-A4?
- Active pixels: 2048 × 264 · Pixel size: 15 × 15 µm. Active area sets both the alignment tolerance and, through capacitance, the achievable bandwidth. A larger element is easier to hit and slower to read.