Back to Home
DField-VS-A4

Spectroscopy Detectors · Scientific spectral CCD

DField-VS-A4

DField-VS-A4 TE-Cooled CCD

A deeply cooled 2048 × 264 scientific CCD detector head with a 30.7 mm-wide active spectral axis, 15 µm pixels and peak quantum efficiency of 95% at 800 nm.

View quote list

Catalog context

Where DField-VS-A4 fits

DField-VS-A4 is listed as DField-VS-A4 TE-Cooled CCD in the Scientific spectral CCD family. The local catalog record provides these first selection fields: Active pixels: 2048 × 264; Pixel size: 15 × 15 µm; Image area: 30.7 × 3.96 mm.

Specifications

Active pixels2048 × 264
Pixel size15 × 15 µm
Image area30.7 × 3.96 mm
Peak quantum efficiency95% at 800 nm
Digitization16 bit
Maximum integration time60 min
TriggerInternal or external TTL
CommunicationUSB 2.0
Power12 V DC, < 50 W

Complete source specification

Model-by-model comparison

The full manufacturer-published comparison is transcribed below so model differences remain visible rather than being reduced to a single range.

ParameterDField-VS-A4
Active pixels (W × H)2048 × 264
Pixel size (W × H)15 × 15 µm
Image area (W × H)30.7 × 3.96 mm
Read noise at 500 kHz< 8 e⁻; < 5 e⁻ typical
Peak quantum efficiency95% at 800 nm
Active-pixel full-well depth> 90 ke⁻
Dark current< 0.1 e⁻/pixel/s
Power supply< 50 W, 12 V DC
Maximum integration time60 min
Trigger modeInternal or external TTL
Communication portUSB 2.0
Operating temperature−20 to +55 °C
Storage temperature−40 to +70 °C
Digitization16 bit

Design and integration details

  • Deep cooling specified at −60 °C with a 25 °C ambient temperature.
  • 30.7 mm-wide sensor captures a broad spectral band in one acquisition.
  • Low read noise and dark current for weak-light spectroscopy.
  • Internal or external TTL triggering with USB 2.0 communication.

Application and connection notes

  • Designed as a spectrograph detector head for Raman, fluorescence and photoluminescence acquisition.
  • The archived source includes the quantum-efficiency curve and CCD mechanical configuration in the product gallery.

Values are transcribed from the archived product table and diagrams. Confirm the final detector, electronics and spectrograph interface for your configuration.

Archived manufacturer product page

System integration

Integration and compatibility

Use these checks to connect DField-VS-A4 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.

Spectral response
Peak quantum efficiency: 95% at 800 nm
Responsivity varies strongly across the stated band. Read the figure at your own wavelength rather than at the peak the headline range implies.
Active area
Active pixels: 2048 × 264 · Pixel size: 15 × 15 µm
Active area sets both the alignment tolerance and, through capacitance, the achievable bandwidth. A larger element is easier to hit and slower to read.

Technical FAQ

Integration questions for DField-VS-A4

What wavelengths does the DField-VS-A4 detect?

Peak quantum efficiency: 95% at 800 nm. Responsivity varies strongly across the stated band. Read the figure at your own wavelength rather than at the peak the headline range implies.

What is the active area of the DField-VS-A4?

Active pixels: 2048 × 264 · Pixel size: 15 × 15 µm. Active area sets both the alignment tolerance and, through capacitance, the achievable bandwidth. A larger element is easier to hit and slower to read.