Beam cleanup
Remove higher-order structure and scatter to recover a clean Gaussian profile.

Spatial Filters · APID Series Adjustable lris Diaphragms
APID Series Adjustable lris Diaphragms
Brief Introduction: The product has a continuously adjustable center hole, which makes it easier for upper frequency of the spectrum to pass through, while other frequency are blocked, thereby changing the frequency of the image on the image plane.
Datasheet (PDF) ↗CAD Model (RAR) ↗Catalog context
APID25-1 is listed as APID Series Adjustable lris Diaphragms in the APID Series Adjustable lris Diaphragms family. The local catalog record provides these first selection fields: Model: APID25-1; Adjustable Diameter Range d(mm): Ø1.5~Ø25; Outter Ring Diameter D(mm): Ø37.
| Model | APID25-1 |
|---|---|
| Adjustable Diameter Range d(mm) | Ø1.5~Ø25 |
| Outter Ring Diameter D(mm) | Ø37 |
| Main Body Material and Treatment | Black anodized aluminium alloy |
| Blade Material | Black spring steel |
| Number of Blade | 13 |
| Handle DiameterW(mm) | Ø3 |
| Overall Height L(mm) | 49 |
| Overall Thickness T(mm) | 5.5 |
| Net Weight(g) | 25 |
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Remove higher-order structure and scatter to recover a clean Gaussian profile.
Produce the smooth wavefront interferometry and holography need at the input.
Combine pinhole filtering and collimation in one assembly ahead of the experiment.
System integration
Use these checks to connect APID25-1 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Adjustable Diameter Range d(mm): Ø1.5~Ø25. Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.
Main Body Material and Treatment: Black anodized aluminium alloy · Blade Material: Black spring steel. Aluminium moves about 23 ppm per kelvin and stainless about 16. In a path where thermal drift is already budgeted, the material of the mount belongs in that budget rather than in the appearance of the part.
Net Weight(g): 25. Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.
Model selection
Compare APID25-1 with the closest available models in the APID Series Adjustable lris Diaphragms family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | APID25-1 (current) | APID22-1 | APID25Z |
|---|---|---|---|
| Optic accepted | Confirm for this model | Confirm for this model | Confirm for this model |
| Adjustment | Ø1.5~Ø25 | Ø1.5~Ø22 | 0~Ø25 |
| Mounting interface | Confirm for this model | Confirm for this model | Confirm for this model |
| Material | Black anodized aluminium alloy | Black anodized aluminium alloy | Black anodized aluminium alloy |