Swapping filters mid-experiment
Change spectral band without disturbing the alignment of the surrounding path.

Filter Mounts · NFH series Filter Mount
NFH series Filter Mount
NFH series Filter Mount — model NFH15-75.
Datasheet (PDF) ↗CAD Model (RAR) ↗Catalog context
NFH15-75 is listed as NFH series Filter Mount in the NFH series Filter Mount family. The local catalog record provides these first selection fields: Optics Thickness(mm): ≤15; Height(mm): 22; Pitch(mm): 1.
| Optics Thickness(mm) | ≤15 |
|---|---|
| Height(mm) | 22 |
| Pitch(mm) | 1 |
| Lock-Mechanism | yes |
| Mounting Hole | M6,Counterboreφ8 |
| Weight(g) | 155 |
Application context
Application guidance is derived from the product family and tied to the model-specific selection fields above.
Change spectral band without disturbing the alignment of the surrounding path.
Hold excitation, emission and notch filters at the correct orientation to the beam.
Set power levels reproducibly ahead of a detector or sample.
System integration
Use these checks to connect NFH15-75 to the surrounding optical, mechanical and control system. Every value shown is taken from this model's own specification record.
Technical FAQ
Optics Thickness(mm): ≤15. Check diameter and thickness together. A holder that accepts the diameter can still fail to retain an optic that is thinner than its minimum, and clear aperture is normally smaller than the optic the mount holds.
Mounting Hole: M6,Counterboreφ8. Match the thread standard and hole pitch before ordering. Metric and imperial hardware interchange only through an adapter, and a thread that is nominally similar is not necessarily the same pitch.
Pitch(mm): 1. Adjuster pitch sets the sensitivity you can actually work at. Confirm whether the stated figure is a total range or a per-revolution increment, and whether the mechanism is locked after adjustment.
Height(mm): 22 · Weight(g): 155. Use the stated geometry and mass to fix beam height, clearance and the load carried by whatever this part is bolted to. These are the numbers that decide whether adjacent components physically collide.
Model selection
Compare NFH15-75 with the closest available models in the NFH series Filter Mount family. Confirm option-dependent values on the final configuration before ordering.
| Selection parameter | NFH15-75 (current) | NFH15-25 |
|---|---|---|
| Optic accepted | ≤15 | ≤15 |
| Adjustment | Confirm for this model | Confirm for this model |
| Mounting interface | M6,Counterboreφ8 | M6,Counterboreφ8 |
| Material | Confirm for this model | Confirm for this model |
Before you specify
Engineering context for choosing this class of component, with the tradeoffs worked through on real specifications.
Raman spectroscopyBalance the ν⁴ signal law, fluorescence background, silicon detector cutoff, and spatial resolution across 532, 638, and 785 nm.
Open guide
Coherent Raman imagingCoherent anti-Stokes Raman scattering, from the four-wave-mixing physics to the hardware: excitation schemes, pulse width versus linewidth, the delay line that carries the spectral axis, and the detection chain.
Open guide