Back to Home
Precisometer · Official representative

X-ray detectors

X-ray sCMOS FDS

Direct fibre-optic coupling protects the sensor while preserving detail in compact, high-resolution X-ray imaging.

X-ray sCMOS FDS

Representative manufacturer photograph; housing and connectors depend on the selected configuration. Select the photograph to enlarge.

Standard configurations
FDS 1.77MP_17_S, 2.86MP_11_S and 7.01MP_17_S
Acquisition
10–37 fps, model dependent
Scintillators
Gadox:Tb and structured CsI

From photon to signal

QE & spectral response.

Full specifications

The published GdOS:Tb absorption curves below describe the scintillator. The complete detector response also depends on scintillator thickness, fibre coupling and sensor response.

Select a figure to inspect the original axes, legend and curves.

Scintillator absorption versus X-ray energy for the thicknesses shown in the legend. Absorption efficiency is not the end-to-end detector quantum efficiency or detective quantum efficiency (DQE). Read the curve together with the selected scintillator thickness and coupling.

GdOS:Tb X-ray absorption efficiency

GdOS:Tb X-ray absorption efficiency — enlarged manufacturer figure

Scintillator absorption versus X-ray energy for the thicknesses shown in the legend. Absorption efficiency is not the end-to-end detector quantum efficiency or detective quantum efficiency (DQE). Read the curve together with the selected scintillator thickness and coupling.

The details behind the selection

Full technical specifications.

Compare sensor configurations, coating options, operating limits and integration details directly below. Check the operating mode and temperature alongside each performance value.

01

Detector formats, readout & cooling specifications

13 parameters
Detector formats, readout & cooling specifications
CharacteristicsFDS 1.77MP_17_SFDS 2.86MP_11_SFDS 7.01MP_17_S
Resolution1608 x 11041944 x 14723216 x 2208
Input Size (mm)14.5 x 9.98.75 x 6.614.5 x 9.9
Pixel Size (µm)94.54
Frame Rate37 fps24 fps10 fps
Full Well Capacity17,000 electrons10,000 electrons
Full Well Capacity (HDR mode)74,000 electrons25,000 electrons
Read Out Noise5 electrons3.5 electrons
Dark Current0.7 electrons/pixel/second
Line Spread Function (FWHM)32 µm18 µm
Sensor Temperature (ºC)Typically, operating at -16°C
Digitization12/16-bit
Exposure50 microseconds up to 60 minutes
Extended Dynamic Range16-bit digitization

Key Features

  • Input sizes: 8.758 x 6.6mm up to 14.5 x 9.9mm
  • Scintillator Gadox:Tb for operation from 3-100 keV, Structured CsI scintillator from 20-300 keV
  • Simultaneous integration / readout enabling 100% duty cycle acquisition
  • Window SDK and Viewer software provided allowing both image corrected acquisition and control of the hardware. Correction functions include bright pixel, flat fielding and dark current removal. Robust basic camera control is also available using GEV commands.
  • OEM versions available on request

Plan the integration

Mechanical drawings.

Enlarge the mounting, connector and camera-outline drawings. Dimensions and model dependencies are retained.

Manufacturer drawings for the detector configurations. Dimensions and input sizes differ by model.

Mechanical drawings & connectors

Mechanical drawings & connectors — enlarged manufacturer figure

Manufacturer drawings for the detector configurations. Dimensions and input sizes differ by model.

Build your enquiry

Start with the detector.

Choose a published configuration, add the integration topics you want to discuss, and keep the exact model in your enquiry.

X-ray sCMOS FDS configuration and enquiry
Your starting configuration

FDS 1.77MP_17_S

Sensor / coating
Fibre-optic direct-coupled sCMOS
Pixels
1608 × 1104
Pixel pitch
9 µm
Active input
14.5 × 9.9 mm
Acquisition
37 fps
Cooling
Typically −16°C
Read noise
5 e−
Optical / mechanical interface
Direct-coupled fibre-optic X-ray input
Spectral response
3–100 keV Gadox:Tb / 20–300 keV CsI

Selected options are requirements for discussion. Compatibility and final performance are confirmed for your configuration.

Review enquiry

Discuss selection, integration and a quotation with Precisometer.

X-ray sCMOS FDS configurations
ConfigurationPixelsPitch / inputCooling / acquisitionRead noise
1608 × 11049 µm
14.5 × 9.9 mm
Typically −16°C
37 fps
5 e−
1944 × 14724.54 µm
8.75 × 6.6 mm
Typically −16°C
24 fps
3.5 e−
3216 × 22084.54 µm
14.5 × 9.9 mm
Typically −16°C
10 fps
3.5 e−

The 7.01MP model label is retained exactly as published; its supplied pixel array is 3216 × 2208. Interface selection is confirmed with the configuration.

Technical overview

Designed around the measurement.

Direct fibre-optic coupling protects the sensor while preserving detail in compact, high-resolution X-ray imaging.

MicrotomographyPCB inspectionSource characterisationPhase-contrast imaging
X-ray sCMOS FDS technical overview
Standard configurationsFDS 1.77MP_17_S, 2.86MP_11_S and 7.01MP_17_S
Acquisition10–37 fps, model dependent
ScintillatorsGadox:Tb and structured CsI

Explore the wider range

Other routes to your measurement.

All Photonic Science products
Product selection

What do you need to measure?

Start with your signal, or search directly for a camera, sensor option or application.

6 product ranges · 13 camera configurations

X-ray sCMOS 4MP
Photonic Science / X-ray detectors

X-ray sCMOS 4MP

A cooled 4-megapixel detector platform with three optical input sizes for laboratory and beamline X-ray imaging.

Resolution
2048 × 2048 pixels
Input sizes
22.5, 48 or 67.2 mm square
3 configurations · specifications
X-ray sCMOS 64MP
Photonic Science / X-ray detectors

X-ray sCMOS 64MP

A large-area X-ray detector built around four fibre-coupled 16MP sCMOS sensors.

Architecture
Four 16MP sCMOS sensors with fibre-optic coupling
Acquisition
Over 5 fps full resolution; subarea / line modes available
1 configurations · specifications
Laue-LT

Representative equipment; the complete configuration depends on your application.

Photonic Science / Laue crystal orientation

Laue-LT

An integrated Laue diffraction system for crystal orientation, with a compact format and manual positioning as standard.

Orientation accuracy, down to
0.2°
Detector input
76 × 105 mm
Explore the solution