X-ray sCMOS 16MP Cooled
Fibre-optic coupled 4096 × 4096 X-ray detection with air or water cooling and two standard active input sizes.
- Resolution
- 4096 × 4096 pixels
- Input sizes
- 36.9 × 36.9 mm / 66.5 × 66.5 mm
Laue crystal orientation
An integrated Laue diffraction system for crystal orientation, with motorised alignment and automated analysis options.
From photon to signal
A system-level QE curve is not published. Laue selection depends on beam energy, detector input, crystal geometry, exposure and orientation accuracy. The model and positioning tables below preserve those system specifications.
The details behind the selection
Compare sensor configurations, coating options, operating limits and integration details directly below. Check the operating mode and temperature alongside each performance value.
| Parameter | Laue-LT | Laue | Laue-XT |
|---|---|---|---|
| Typical exposure time | 120–240 s | 1–30 s | 1–30 s |
| Maximum sample size (L × D × H) | 50 × 50 × 26.5 mm | Horizontal: 250 × 250 × 40 mm; vertical: 250 × 150 × 40 mm | 450 × 250 × 250 mm |
| Scanning area | Horizontal: 50 × 26.5 mm; vertical: 50 × 50 mm | Horizontal: 250 × 40 mm; vertical: 250 × 150 mm | 250 × 250 mm |
| Beam size on sample | Adjustable down to 1 mm | 450 µm; 250 µm fine focus | 450 µm; 250 µm fine focus |
| Active detector input | 76 × 105 mm | 155 × 105 mm | 155 × 105 mm |
| Orientation accuracy, down to | 0.2° | 0.1° | 0.1° |
| Sample alignment camera | Not included | Included as standard | Included as standard |
| Energy range | 5–50 keV | 5–29 keV | 5–29 keV |
| — | Laue | Laue-LT |
|---|---|---|
| Active Input Area (h) x (v) mm | ≈ 155 x 105 | ≈ 76 x 105 |
| Input Pixel Size of 61.1 µm square | 2570 x 1710 | 1285 x 1710 |
| Detector Exposure Time Range | 1 ms to 15 min | 1 ms to 15 min |
| Pixel Binning Option | ✓ | ✓ |
| Typical Exposure Time Ranges | 1 s - 30 s | 120 s - 240 s |
| Pixel Binning from 1x1 to 8x8 | ✓ | ✓ |
| Crystal Orientation Down to Accuracy | 0.1° | 0.2° |
| Solution from Random Si Orientation | ≈ 5 s | ≈ 5 s |
| Alignment Camera (top viewing of the sample) | ✓ | × |
| Laser Distance Measurement Tool | ✓ | Pointer arm |
| Motorised Axis Z: +/- 20 mm, X: +/- 25 mm, Y: +/- 100 mm adjustments with 20 microns accuracy and maximum 10kg load capacity | ✓ | Manual stages as standard; Maximum Y movement of +/- 10 mm |
| Automated Point-Scanning Routines | ✓ | × |
| Motorised Goniometer and Rotation Axis | ✓ | Manual as standard |
| Beam Size on the Sample | 450 µm | Adjustable down to 1 mm |
| Sealed X-ray Tube with Tungsten Target | ✓ | ✓ |
| Average Spectrum on Sample (Bremsstrahlung) | 5 - 29 keV | 5 - 50 keV |
| PSEL X-ray Generator Fast automatic ramp up/down procedures software controlled up to 50 kV and 1 mA: ie. 50W power | ✓ | ✓ |
| Forced-Air Cooling | ✓ | ✓ |
| Requires Single Mains Power Connection | ✓ | ✓ |
| Standard Build Cabinet Dimensions | W 689 x D 676 x H 800 mm | W 649 x D 450 x H 874 mm |
| Custom Workbench Cabinet mount with space for monitor, keyboard and mouse (150 x 75 x 83 cm) | ✓ | ✓ |
| Reference Si Sample | ✓ | ✓ |
| X-ray Source Alignment Camera | ✓ | × |
| PSEL Market-Leading Laue Software | ✓ | ✓ |
The comparison sheet describes the configurations and options in that revision. The newer family brochure adds Laue-XT and the sample envelopes above; confirm selected positioning and cabinet options.
Build your enquiry
Capture the system requirements and integration details you want to discuss with Precisometer.
Technical overview
An integrated Laue diffraction system for crystal orientation, with motorised alignment and automated analysis options.
| Orientation accuracy, down to | 0.1° |
|---|---|
| Detector input | 155 × 105 mm |
| Typical exposure | 1–30 s typical |
| Energy range on sample | 5–29 keV |
| Maximum sample envelope | 450 × 250 × 250 mm |
Explore the wider range
6 product ranges · 16 camera configurations

Fibre-optic coupled 4096 × 4096 X-ray detection with air or water cooling and two standard active input sizes.

Fibre-optic coupled 4096 × 4096 X-ray detection with a compact, brass-shielded housing optimised for short exposures.

Direct fibre-optic coupling protects the sensor while preserving detail in compact, high-resolution X-ray imaging.

A cooled 4-megapixel detector platform with three optical input sizes for laboratory and beamline X-ray imaging.

A large-area X-ray detector built around four fibre-coupled 16MP sCMOS sensors.

A back-reflection detector with a central beam path for real-time Laue diffraction and crystal orientation.